MRI-scale histology validates spatial sensitivity of in-vivo MRI-based axon radius estimation
Open Access
- 5 December 2025
- journal article
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Abstract
The axon radius holds promise as a clinical MRI biomarker for neurological disorders. However, in-vivo MRI estimation appears infeasible on clinical scanners and lacks experimental validation. Crucially, existing histology is only sparsely sampled, enabling primarily qualitative assessment. Here, we use large-scale human brain histology, sampling 46 million axons across 35 corpus callosum regions with MRI-like sizes. By demonstrating a significant spatial correlation with histology on an advanced research scanner, we provide quantitative proof that MRI radius estimates reflect underlying microstructure—a critical milestone. The next milestone—translation to clinical scanners—appears feasible with now-available high-gradient systems according to simulations, but would require substantial SNR gains. Yet, we also identify a sensitivity bottleneck in current modeling that may offer a complementary path to improved sensitivity through future modeling advances. Overall, we provide promising evidence for the validity of MRI-based axon radius estimation and identify challenges that must be solved for clinical adoption.Keywords
Funding Information
- H2020 European Research Council (FP7/2007-2013)
- ERC (616905)
- Deutsche Forschungsgemeinschaft (MO 2397/5-1, MO 2397/5-2, MO 2249/3-1, MO 2249/3-2)
- Emmy Noether (MO 2397/4-1, MO 2397/4-2)
- Deutsche Forschungsgemeinschaft (347592254 (WE 5046/4-2))
- H2020 European Research Council (101089218)
This publication has 100 references indexed in Scilit:
- The variability of MR axon radii estimates in the human white matterHuman Brain Mapping, 2021
- Quantitative mapping of the per‐axon diffusion coefficients in brain white matterMagnetic Resonance in Medicine, 2015
- PGSE,OGSE, and sensitivity to axon diameter in diffusionMRI: Insight from a simulation studyMagnetic Resonance in Medicine, 2015
- Temperature‐induced changes of magnetic resonance relaxation times in the human brain: A postmortem studyMagnetic Resonance in Medicine, 2013
- Axcaliber: A method for measuring axon diameter distribution from diffusion MRIMagnetic Resonance in Medicine, 2008
- Use of spherical harmonic deconvolution methods to compensate for nonlinear gradient effects on MRI imagesMagnetic Resonance in Medicine, 2004
- Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imagingMagnetic Resonance in Medicine, 1999
- An analytical model of restricted diffusion in bovine optic nerveMagnetic Resonance in Medicine, 1997
- The rician distribution of noisy mri dataMagnetic Resonance in Medicine, 1995
- Cytological and quantitative characteristics of four cerebral commissures in the rhesus monkeyJournal of Comparative Neurology, 1990