Hybrid and fully‐etched surface implants in periodontally healthy patients: A comparative retrospective study on marginal bone loss
- 29 May 2017
- journal article
- research article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 19 (4) , 663-670
Abstract
Background: Human studies on implants with the same design but with different surfaces are lacking at the present time.Purpose: The aim of this study was to compare the survival rate of and marginal bone loss (MBL) around 2 types of implants with the same design, but with different surfaces: fully “sandblasted and double‐etched” (SDE) implants and hybrid (H) implants, with an apical SDE‐surface and a coronal machined‐surface.Materials and methods: The SDE‐ and H‐surfaces were previously analyzed under SEM and profilometer. Implants were placed in partially edentulous periodontally healthy patients requiring single implant‐restoration, in either mandible or maxilla, with cement‐retained prosthetic restoration. Twelve months after prosthetic loading, MBL in relation to prosthetic abutment height (AH), calculated radiographically, was statistically analyzed.Results: SEM and profilometer analyses revealed no differences between the SDE‐surfaces of either SDE‐ or H‐implants. Transverse ridges and grooves characterized the machined portion of H‐implants, clearly influencing the profilometer analysis. In 75 patients, 37 SDE and 38 H‐implants were placed and all functioned completely after 12 months. In both SDE‐ and H‐groups, MBL had a significant inverse relationship with AH, with greater intercept and negative slope for SDE‐group and intersection of the 2 regression lines at AH = 2 mm.Conclusions: A 100% survival rate was recorded for SDE‐ and H‐implants placed in pristine bone of periodontally healthy patients; MBL was limited and similar in both SDE‐ and H‐groups; the higher the prosthetic AH, the lesser the MBL around implants; H‐implants could reduce bone loss most effectively with abutments lower than 2 mm, realistically exploitable on thin biotypes; SDE‐implants could reduce bone loss most effectively with abutments greater than 2 mm, realistically exploitable on thick biotypes.Keywords
This publication has 29 references indexed in Scilit:
- Experimental periodontitis and peri‐implantitis in dogsClinical Oral Implants Research, 2012
- Histological and immunohistochemical evaluation of the peri-implant soft tissues around machined and acid-etched titanium healing abutments: a prospective randomised studyClinical Oral Investigations, 2011
- A Prospective, Multicenter, Randomized‐Controlled 5‐Year Study of Hybrid and Fully Etched Implants for the Incidence of Peri‐ImplantitisJournal of Periodontology, 2010
- A 3-year prospective radiographic evaluation of marginal bone level around different implant systemsJournal of Oral Rehabilitation, 2010
- Platform switching and marginal bone‐level alterations: the results of a randomized‐controlled trialClinical Oral Implants Research, 2009
- Declaration of Helsinki, 2008Journal of Postgraduate Medicine, 2009
- Surface treatments of titanium dental implants for rapid osseointegrationDental Materials, 2007
- Turned, Machined Versus Double‐Etched Dental Implants In VivoClinical Implant Dentistry and Related Research, 2007
- Bone reactions to longstanding functional load at implants: an experimental study in dogsJournal of Clinical Periodontology, 2005
- Fixed implant‐supported prostheses in the edentulous maxilla. A five‐year follow‐up report.Clinical Oral Implants Research, 1994