Abstract
Purpose: To evaluate the use of an audio/visual (A/V) system in pediatric patients as an alternative to sedation in magnetic resonance imaging (MRI) in terms of wait times, image quality, and patient experience.Materials and Methods: Pediatric MRI examinations from April 8 to August 11, 2008 were compared to those 1 year prior to the installation of the A/V system. Data collected included age, requisition receive date, scan date, and whether sedation was used. A posttest questionnaire was used to evaluate patient experience. Image quality was assessed by two radiologists.Results: Over the 4 months in 2008 there was an increase of 7.2% (115; P < 0.05) of pediatric patients scanned and a decrease of 15.4%, (67; P = 0.32) requiring sedation. The average sedation wait time decreased by 33% (5.8 months) (P < 0.05). Overall, the most positively affected group was the 4–10 years. The questionnaire resulted in 84% of participants expressing a positive reaction to the A/V system. Radiological evaluation revealed no changes in image quality between A/V users and sedates.Conclusion: The A/V system was a successful method to reduce patient motion and obtain a quality diagnostic MRI without the use of sedation in pediatric patients. It provided a safer option, a positive experience, and decreased wait times. J. Magn. Reson. Imaging 2009.Keywords
This publication has 9 references indexed in Scilit:
- Avoiding sedation in pediatric radiologyPediatric Radiology, 2008
- Claustrophobia during magnetic resonance imaging: Cohort study in over 55,000 patientsJournal of Magnetic Resonance Imaging, 2007
- MR imaging of claustrophobic patients in an open 1.0T scanner: Motion artifacts and patient acceptability compared with closed bore magnetsEuropean Journal of Radiology, 2007
- Claustrophobia and premature termination of magnetic resonance imaging examinationsJournal of Magnetic Resonance Imaging, 2007
- Use of Virtual Reality Distraction to Reduce Claustrophobia Symptoms during a Mock Magnetic Resonance Imaging Brain Scan: A Case ReportCyberPsychology & Behavior, 2007
- Practice MRI: Reducing the need for sedation and general anaesthesia in children undergoing MRIAustralasian Radiology, 2006
- MRI-compatible audio/visual system: impact on pediatric sedationPediatric Radiology, 2001
- Sedation Procedures in MR Imaging: Safety, Effectiveness, and Nursing Effect on ExaminationsRadiology, 2000
- Sedation and general anaesthesia in children undergoing MRI and CT: adverse events and outcomesBritish Journal of Anaesthesia, 2000