High Temperature Performance of Concrete Confinement by MWCNT Modified Epoxy Based Fiber Reinforced Composites
Open Access
- 18 December 2022
- Vol. 15 (24) , 9051
Abstract
The conventional method of fiber reinforced polymer (FRP) wrapping around concrete columns uses epoxy as the binder along with synthetic or natural fibers such as carbon, glass, basalt, jute, sisal etc. as the reinforcement. However, the thermal stability of epoxy is a major issue in application areas prone to fire exposure. The current work addressed this major drawback of epoxy by modifying it with a nanofiller, such as multiwalled carbon nanotubes (MWCNT), and reinforcing it using basalt and sisal fibers. The effect of exposure to elevated temperature on the behavior of concrete cylinders externally confined with these FRP systems was analyzed. Three types of specimens were considered: unconfined; confined with sisal fiber reinforced polymer (SFRP); and confined with hybrid sisal basalt fiber reinforced polymer (HSBFRP) specimens. The test samples were exposed to elevated temperature regimes of 100 °C, 200 °C, 300 °C and 400 °C for a period of 2 h. The compressive strengths of unconfined specimens were compared with various confined specimens, and from the test results, it was evident that the mechanical and thermal durability of the FRP systems was substantially enhanced by MWCNT incorporation. The reduction in the compressive strength of the FRP-confined specimens varied depending on the type of the confinement. After two hours of exposure at 400 °C, the compressive strength corresponding to the epoxy–HSBFRP-confined specimens were improved by 15%, whereas a 50% increase in strength corresponding to MWCNT-incorporated epoxy–HSBFRP-confined specimens was observed with respect to unconfined unexposed specimens. The MWCNT-modified epoxy-incorporated FRP-confined systems demonstrated superior performance even at elevated temperatures in comparison to unconfined specimens at ambient temperatures.Keywords
This publication has 39 references indexed in Scilit:
- Hybrid Confinement of Concrete by Fiber-Reinforced Polymer Sheets and Fiber Ropes under Cyclic Axial Compressive LoadingJournal of Composites for Construction, 2013
- Mechanical property evaluation of sisal–jute–glass fiber reinforced polyester compositesComposites Part B: Engineering, 2013
- Axial capacity of post-heated square columns wrapped with FRP compositesCement and Concrete Composites, 2011
- Behavior of FRP-confined concrete after high temperature exposureConstruction and Building Materials, 2011
- Cross sectional shape effects on the performance of post-heated reinforced concrete columns wrapped with FRP compositesComposite Structures, 2011
- FRP-confined Concrete Cylinders: Axial Compression Experiments and Strength ModelJournal of Reinforced Plastics and Composites, 2010
- Experimental and Computational Studies on High-Strength Concrete Circular Columns Confined by Aramid Fiber-Reinforced Polymer SheetsJournal of Composites for Construction, 2009
- Structural Performance of Concrete Confined with Hybrid FRP CompositesJournal of Reinforced Plastics and Composites, 2008
- Polyethylene multiwalled carbon nanotube compositesPolymer, 2005
- Strength and durability performance of concrete axially loaded members confined with AFRP composite sheetsComposites Part B: Engineering, 2002