Disagreement in cardiac output measurements between fourth-generation FloTrac and critical care ultrasonography in patients with circulatory shock: a prospective observational study
Open Access
- 11 April 2019
- journal article
- research article
- Published by Springer Nature in Journal of Intensive Care
- Vol. 7 (1) , 21
Abstract
Cardiac output measurements may inform diagnosis and provide guidance of therapeutic interventions in patients with hemodynamic instability. The FloTrac™ algorithm uses uncalibrated arterial pressure waveform analysis to estimate cardiac output. Recently, a new version of the algorithm has been developed. The aim was to assess the agreement between FloTrac™ and routinely performed cardiac output measurements obtained by critical care ultrasonography in patients with circulatory shock. A prospective observational study was performed in a tertiary hospital from June 2016 to January 2017. Adult critically ill patients with circulatory shock were eligible for inclusion. Cardiac output was measured simultaneously using FloTrac™ with a fourth-generation algorithm (COAP) and critical care ultrasonography (COCCUS). The strength of linear correlation of both methods was determined by the Pearson coefficient. Bland-Altman plot and four-quadrant plot were used to track agreement and trending ability. Eighty-nine paired cardiac output measurements were performed in 17 patients during their first 24 h of admittance. COAP and COCCUS had strong positive linear correlation (r2 = 0.60, p < 0.001). Bias of COAP and COCCUS was 0.2 L min−1 (95% CI − 0.2 to 0.6) with limits of agreement of − 3.6 L min−1 (95% CI − 4.3 to − 2.9) to 4.0 L min−1 (95% CI 3.3 to 4.7). The percentage error was 65.6% (95% CI 53.2 to 77.3). Concordance rate was 64.4%. In critically ill patients with circulatory shock, there was disagreement and clinically unacceptable trending ability between values of cardiac output obtained by uncalibrated arterial pressure waveform analysis and critical care ultrasonography. Clinicaltrials.gov, NCT02912624 , registered on September 23, 2016Keywords
This publication has 31 references indexed in Scilit:
- A Critical Review of the Ability of Continuous Cardiac Output Monitors to Measure Trends in Cardiac OutputAnesthesia & Analgesia, 2010
- The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studiesThe Lancet, 2007
- Agreement Between Methods of Measurement with Multiple Observations Per IndividualJournal of Biopharmaceutical Statistics, 2007
- Acute Physiology and Chronic Health Evaluation (APACHE) IV: Hospital mortality assessment for today’s critically ill patients*Critical Care Medicine, 2006
- Does dopamine administration in shock influence outcome? Results of the Sepsis Occurrence in Acutely Ill Patients (SOAP) Study*Critical Care Medicine, 2006
- Transthoracic echocardiography for cardiopulmonary monitoring in intensive careEuropean Journal of Anaesthesiology, 2004
- Transthoracic echocardiography for cardiopulmonary monitoring in intensive careEuropean Journal of Anaesthesiology, 1999
- A New Simplified Acute Physiology Score (SAPS II) Based on a European/North American Multicenter StudyJAMA, 1993
- A new Simplified Acute Physiology Score (SAPS II) based on a European/North American multicenter studyJAMA, 1993
- Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window.Circulation, 1984