Overall Evaluation of Combustion and NOx Emissions for a Down-Fired 600 MWe Supercritical Boiler with Multiple Injection and Multiple Staging
Authors:
- 26 March 2013
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 47 (9) , 4850-4858
Abstract
To achieve significant reductions in NOx emissions and to eliminate strongly asymmetric combustion found in down-fired boilers, a deep-air-staging combustion technology was trialed in a down-fired 600 MWe supercritical utility boiler. By performing industrial-sized measurements taken of gas temperatures and species concentrations in the near wing-wall region, carbon in fly ash and NOx emissions at various settings, effects of overfire air (OFA) and staged-air damper openings on combustion characteristics, and NOx emissions within the furnace were experimentally determined. With increasing the OFA damper opening, both fluctuations in NOx emissions and carbon in fly ash were initially slightly over OFA damper openings of 0–40% but then lengthened dramatically in openings of 40–70% (i.e., NOx emissions reduced sharply accompanied by an apparent increase in carbon in fly ash). Decreasing the staged-air declination angle clearly increased the combustible loss but slightly influenced NOx emissions. In comparison with OFA, the staged-air influence on combustion and NOx emissions was clearly weaker. Only at a high OFA damper opening of 50%, the staged-air effect was relatively clear, i.e., enlarging the staged-air damper opening decreased carbon in fly ash and slightly raised NOx emissions. By sharply opening the OFA damper to deepen the air-staging conditions, although NOx emissions could finally reduce to 503 mg/m3 at 6% O2 (i.e., an ultralow NOx level for down-fired furnaces), carbon in fly ash jumped sharply to 15.10%. For economical and environment-friendly boiler operations, an optimal damper opening combination (i.e., 60%, 50%, and 50% for secondary air, staged-air, and OFA damper openings, respectively) was recommended for the furnace, at which carbon in fly ash and NOx emissions attained levels of about 10% and 850 mg/m3 at 6% O2, respectively.Keywords
This publication has 20 references indexed in Scilit:
- CFD modelling of air-fired and oxy-fuel combustion in a large-scale furnace at Loy Yang A brown coal power stationFuel, 2012
- Effect of the anthracite ratio of blended coals on the combustion and NOx emission characteristics of a retrofitted down-fired 660-MWe utility boilerApplied Energy, 2012
- Asymmetric combustion characteristics and NOx emissions of a down-fired 300 MWe utility boiler at different boiler loadsEnergy, 2012
- Improving the Performance of a 300 MW Down-Fired Pulverized-Coal Utility Boiler by Inclining Downward the F-Layer Secondary AirEnergy & Fuels, 2010
- Influence of Staged-Air on Airflow, Combustion Characteristics and NOx Emissions of a Down-Fired Pulverized-Coal 300 MWe Utility Boiler with Direct Flow Split BurnersEnvironmental Science & Technology, 2010
- Numerical simulations of the slagging characteristics in a down-fired, pulverized-coal boiler furnaceFuel Processing Technology, 2010
- Numerical investigation of full scale coal combustion model of tangentially fired boiler with the effect of mill ductingHeat and Mass Transfer, 2009
- Effect of Air-Staging on Anthracite Combustion and NOx FormationEnergy & Fuels, 2008
- Effect of Volatile−Char Interaction on the NO Emission from Coal CombustionEnvironmental Science & Technology, 2008
- Nitric Oxide Reduction in Coal Combustion: Role of Char Surface Complexes in Heterogeneous ReactionsEnvironmental Science & Technology, 2002