Spectral discrimination of Čerenkov radiation in scintillating dosimeters
Authors:
- A‐M. FrelinAFA‐M. Frelin
- J‐M. FontbonneJFJ‐M. Fontbonne
- G. BanGBG. Ban
- J. ColinJCJ. Colin
- M. LabalmeMLM. Labalme
- A. BatallaABA. Batalla
- A. IsambertAIA. Isambert
- A. VelaAVA. Vela
- T. LerouxTLT. Leroux
- 30 August 2005
- journal article
- Published by Wiley in Medical Physics
- Vol. 32 (9) , 3000-3006
Abstract
Radiation therapy accelerators require highly accurate dose deposition and the output must be monitored frequently and regularly. Ionization chambers are the primary tool for this control, but their size, their high voltage needed, and the correction needed for electrons make them unsuitable for use during patient treatment. We have developed a small (1‐mm‐diam and 1‐mm‐long active part), flexible, and water‐equivalent dosimeter. It is suitable for photon and electron beams without corrections, and performs on line dose measurements. This detector is based on only one scintillating fiber and a CCD camera. A new signal processing is used to remove the effect of Čerenkov radiation background, which only requires a preliminary calibration. Central‐axis depth‐dose distribution comparisons have been achieved with standard ionization chambers, over a range from 8 to 25 MV photons and from 6 to 21 MeV electrons in order to validate this calibration. Results show a very good agreement, with less than 1% difference between the two detectors.Keywords
This publication has 11 references indexed in Scilit:
- Scintillating fiber dosimeter for radiation therapy acceleratorIEEE Transactions on Nuclear Science, 2002
- A temporal method of avoiding the Cerenkov radiation generated in organic scintillator dosimeters by pulsed mega-voltage electron and photon beamsPhysics in Medicine & Biology, 2002
- A miniature "scintillator-fiberoptic-PMT" detector system for the dosimetry of small fields in stereotactic radiosurgeryIEEE Transactions on Nuclear Science, 2001
- SIC, an intracerebral radiosensitive probe for in vivo neuropharmacology investigations in small laboratory animals: theoretical considerations and practical characteristicsIEEE Transactions on Nuclear Science, 2000
- Miniature scintillating detector for small field radiation therapyMedical Physics, 1999
- Radiation-induced light in optical fibers and plastic scintillators: application to brachytherapy dosimetryIEEE Transactions on Nuclear Science, 1996
- Direct reading measurement of absorbed dose with plastic scintillators—The general concept and applications to ophthalmic plaque dosimetryMedical Physics, 1996
- Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerationsPhysics in Medicine & Biology, 1992
- Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurementsPhysics in Medicine & Biology, 1992
- Cerenkov light generated in optical fibres and other light pipes irradiated by electron beamsPhysics in Medicine & Biology, 1992