Stability of DC-link voltage affected by phase-locked loop for DFIG-based wind turbine connected to a weak AC system
Authors:
- 1 October 2014
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2600-2606
Abstract
The paper investigates the stability of DC-link voltage, in electromagnetic time scale, of doubly fed induction generator (DFIG) based wind turbine attached to a weak AC system. In weak AC system, the dynamic of phase-locked loop (PLL) is coupled with DFIG converters' control. A reduced order model is proposed for stability analysis of DFIG DC-link voltage. Eigenvalue analysis shows that PLL, active power control (APC) and reactive power control (RPC) of rotor side converter (RSC) mainly participate in dominant oscillation mode of control system. The interactions between PLL and RSC control damage the stability of DC-link voltage in weak grid. Synchronizing and damping components defined by PLL are presented for stability analysis physically. Each control's contribution to synchronizing and damping components is analyzed for different grid strengths and PLL gains. It clearly illustrates how PLL and RSC control interact leading to system instability. Time domain simulation of a detailed model was carried out to verify the validity of the analysis above.Keywords
This publication has 11 references indexed in Scilit:
- Effect of reactive power control on stability of DC-link voltage control in VSC connected to weak grid2014
- Stability of DC-link voltage as affected by phase locked loop in VSC when attached to weak grid2014
- Modeling, Analysis, and Suppression of the Impact of Full-Scale Wind-Power Converters on Subsynchronous DampingIEEE Systems Journal, 2013
- Model of a VSC HVDC terminal attached to a weak AC system2004
- The impact of large scale wind power generation on power system oscillationsElectric Power Systems Research, 2003
- Analytical modelling of HVDC-HVAC systemsIEEE Transactions on Power Delivery, 1999
- The connection between modal analysis and electric torque analysis in studying the oscillation stability of multi-machine power systemsInternational Journal of Electrical Power & Energy Systems, 1997
- Doubly fed induction generator usingback-to-back PWM convertersand its application to variable-speed wind-energy generationIEE Proceedings - Electric Power Applications, 1996
- Concepts for design of FACTS controllers to damp power swingsIEEE Transactions on Power Systems, 1995
- Concepts of Synchronous Machine Stability as Affected by Excitation ControlIEEE Transactions on Power Apparatus and Systems, 1969