Improved Performance of the Potentiometric Biosensor for the Determination of Creatinine
- 25 February 2007
- journal article
- research article
- Published by Taylor & Francis in Analytical Letters
- Vol. 40 (1) , 39-52
Abstract
Contemporary methods of analyzing creatinine engage chemicals harmful to the environment and generate large volumes of waste disposals. By introducing a membrane‐based potentiometric biosensor with immobilized creatinine deaminase, the measurements can be performed by miniaturized portable devices that are easy to handle and allow rapid analysis with minimum consumption of chemicals. Thus, the enzymatic creatinine biosensors were revisited and optimized with respect to repeatability, sensitivity, limit of detection (LOD), and response time. A detection limit of 0.3 µM and a sensitivity of 58.78±0.03 mV (23.5°C) were obtained in tris buffer at pH=7.4 after introduction of shielding of all electronics and software filtering. Measurements performed by flow injection analysis (FIA) showed that the response time could be lowered to approximately 30 sec using sample volumes of 30 µl. Interferences were corrected for by application of the Nicolsky‐Eisenman equation, thus allowing determination of creatinine in matrices resembling those of clinical measurements. Investigations of sandwich structures showed that the sensitivity decreased as a function of the number of membranes on top of the immobilized layer of active creatinine deaminase. It was thus shown that the sensitivity depends on the distance of diffusion of species from the sample solution through the membranes to the enzyme.Keywords
This publication has 29 references indexed in Scilit:
- Influence of the spacer length on the activity of enzymes immobilised on nylon/polyGMA membranesJournal of Molecular Catalysis B: Enzymatic, 2003
- Development of a Creatinine ELISA and an Amperometric Antibody-Based Creatinine Sensor with a Detection Limit in the Nanomolar RangeAnalytical Chemistry, 2000
- Ion sensors: current limits and new trendsAnalytica Chimica Acta, 1999
- Comparison of flow injection analytical biosystems based on open-tube and packed-bed enzyme reactorsAnalytica Chimica Acta, 1998
- Suitable potentiometric enzyme sensors for urea and creatinineThe Analyst, 1990
- Characterization of biosensors based on membranes containing a conducting polymerAnalytica Chimica Acta, 1989
- Optimisation of poly(vinyl chloride) matrix membrane ion-selective electrodes for ammonium ionsThe Analyst, 1988
- Homogeneous ferrocene-mediated amperometric immunoassayAnalytical Chemistry, 1986
- Creatinine-selective enzyme electrodesAnalytica Chimica Acta, 1983
- THE EQUILIBRIUM BETWEEN CREATINE AND CREATININE, IN AQUEOUS SOLUTION. THE EFFECT OF HYDROGEN IONJournal of the American Chemical Society, 1925