A multicenter study to evaluate harmonization of assays for N-terminal propeptide of type I procollagen (PINP): a report from the IFCC-IOF Joint Committee for Bone Metabolism
- 23 March 2019
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 57 (10) , 1546-1555
Abstract
Background: Biochemical bone turnover markers (BTM) are useful tools to assess bone remodeling at the cellular level. N-terminal propeptide of type I procollagen (PINP) has been recommended as a reference marker for bone formation in research studies. Methods: We describe the results of a multicenter study for routine clinical laboratory assays for PINP in serum and plasma. Four centers (Athens, Greece [GR], Copenhagen, Denmark [DK], Liege, Belgium [BE] and Sheffield, United Kingdom [UK]) collected serum and plasma (EDTA) samples from 796 patients presenting to osteoporosis clinics. Specimens were analyzed in duplicate with each of the available routine clinical laboratory methods according to the manufacturers’ instructions. Passing-Bablok regressions, Bland-Altman plots, V-shape evaluation method and the concordance correlation coefficient for PINP values between serum and plasma specimens and between methods were used to determine the agreement between results. A generalized linear model was employed to identify possible variables that affected the relationship between the methods. Results: We showed that both EDTA plasma and serum were suitable for PINP determination. We observed a significant proportional bias between Orion radioimmunoassay and the automated methods for PINP (Roche Cobas and IDS iSYS), which both gave very similar results. The multivariate model did not improve the excellent correlation that was observed between the methods. Conclusions: Harmonization of PINP assays is possible by applying a correction factor or correctly assigning the values of the calibrators. This work will benefit from further collaboration between assays manufacturers and clinical laboratory professionals.Keywords
This publication has 21 references indexed in Scilit:
- Aminoterminal propeptide of type I procollagen (PINP) in chronic kidney disease patients: the assay matters.Clinica Chimica Acta, 2013
- IDS iSYS automated intact procollagen-1-N-terminus pro-peptide assay: method evaluation and reference intervals in adults and childrenClinical Chemistry and Laboratory Medicine (CCLM), 2013
- Measurement of aminoterminal propeptide of type I procollagen (PINP) in serumClinical Biochemistry, 2012
- Comparison of total and intact aminoterminal propeptide of type I procollagen assays in patients with breast cancer with or without bone metastasesAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2011
- International Osteoporosis Foundation and International Federation of Clinical Chemistry and Laboratory Medicine Position on bone marker standards in osteoporosisClinical Chemistry and Laboratory Medicine (CCLM), 2011
- Validation of an automated intact N-terminal propeptide of type I procollagen (PINP) assayClinical Biochemistry, 2010
- A randomised, double-blinded, placebo-controlled, trial to determine the individual response in bone turnover markers to lasofoxifene therapyBone, 2009
- Evaluation of a Fully Automated Serum Assay for Total N-Terminal Propeptide of Type I Collagen in Postmenopausal OsteoporosisClinical Chemistry, 2008
- Response of Biochemical Markers of Bone Turnover to Hormone Replacement Therapy: Impact of Biological VariabilityJournal of Bone and Mineral Research, 1998
- Universal standardization for dual X-ray absorptiometry: Patient and phantom cross-calibration resultsJournal of Bone and Mineral Research, 1994