Switching Strategies for Fault Tolerant Operation of Single DC-link Dual Converters
- 14 July 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 27 (2) , 509-518
Abstract
This paper proposes a method that allows the operation with direct torque control under incipient faults of the power switching devices in single dc-link dual inverters. Once the fault onset of the switching device is detected, the troubled devices are put under trigger suppression to regain operation. The proposed control algorithm makes use of additional states, termed opportunistic states, to maintain control of the induction machine. Simulations and experimental results confirm the capabilities of the technique for up to six devices under trigger suppression.Keywords
This publication has 27 references indexed in Scilit:
- Hybrid PWM Strategy of SVPWM and VSVPWM for NPC Three-Level Voltage-Source InverterIEEE Transactions on Power Electronics, 2010
- Voltage Control of Three-Stage Hybrid Multilevel Inverter Using Vector TransformationIEEE Transactions on Power Electronics, 2010
- Fault-Tolerant Operation of a Battery-Energy-Storage System Based on a Multilevel Cascade PWM Converter With Star ConfigurationIEEE Transactions on Power Electronics, 2010
- Hybrid Cascaded H-Bridge Multilevel-Inverter Induction-Motor-Drive Direct Torque Control for Automotive ApplicationsIEEE Transactions on Industrial Electronics, 2009
- Improving Digital System Diagnostics Through Prognostic and Health Management (PHM) TechnologyIEEE Transactions on Instrumentation and Measurement, 2008
- Effect of Zero-Vector Placement in a Dual-Inverter Fed Open-End Winding Induction Motor Drive With Alternate Sub-Hexagonal Center PWM Switching SchemeIEEE Transactions on Power Electronics, 2008
- Space-vector-based PWM switching strategies for a three-level dual-inverter-fed open-end winding induction motor drive and their comparative evaluationIET Electric Power Applications, 2008
- Switching Technique for Dual-Two level Inverter Supplied by Two Separate SourcesAPEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition, 2007
- Space vector PWM control of dual inverter fed open-end winding induction motor drive2002
- SRM inverter topologies: a comparative evaluationIEEE Transactions on Industry Applications, 1991