Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
Open Access
- 10 February 2022
- journal article
- research article
- Published by MDPI AG in Electronics
- Vol. 11 (4) , 534
Abstract
An acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component mismatch. These filter features greatly simplify the implementation of the electronic cochlea in CMOS technologies. An exemplary filter bank designed and simulated in an X-FAB 180 nm CMOS process is presented, which consumes 1.25–34.75 nW of power per individual filter when supplied with 0.5 V. The 11-channel filter bank covers a 20–20 kHz band, while the Q-factor of each channel can be tuned from 2 to 40. The simulation-predicted sensitivities of Q and ω0 to process/voltage/temperature (PVT) variations are less than 1%. The input-referred noise is no greater than 22 µVRMS, and the dynamic range is at least 68 dB for all filters in the bank.Keywords
Funding Information
- National Science Centre of Poland (2016/23/B/ST7/03733)
This publication has 21 references indexed in Scilit:
- A 6 mW, 5,000-Word Real-Time Speech Recognizer Using WFST ModelsIEEE Journal of Solid-State Circuits, 2014
- A Fully-Implantable Cochlear Implant SoC With Piezoelectric Middle-Ear Sensor and Arbitrary Waveform Neural StimulationIEEE Journal of Solid-State Circuits, 2014
- ${\rm A}~6~{\mu{\rm W}}$ per Channel Analog Biomimetic Cochlear Implant Processor Filterbank Architecture With Across Channels AGCIEEE Transactions on Biomedical Circuits and Systems, 2014
- Asynchronous Binaural Spatial Audition Sensor With 2$\,\times\,$64$\,\times\,$4 Channel OutputIEEE Transactions on Biomedical Circuits and Systems, 2013
- Making Use of Auditory Models for Better Mimicking of Normal Hearing Processes With Cochlear Implants: The SAM Coding StrategyIEEE Transactions on Biomedical Circuits and Systems, 2012
- An Ultra-Low-Power Programmable Analog Bionic Ear ProcessorIEEE Transactions on Biomedical Engineering, 2005
- Mechanical bases of frequency tuning and neural excitation at the base of the cochlea: Comparison of basilar-membrane vibrations and auditory-nerve-fiber responses in chinchillaProceedings of the National Academy of Sciences, 2000
- Improved implementation of the silicon cochleaIEEE Journal of Solid-State Circuits, 1992
- An analog electronic cochleaIEEE Transactions on Acoustics, Speech, and Signal Processing, 1988
- Mossbauer Measurements of the Mechanical Response to Single-Tone and Two-Tone Stimuli at the Base of the Chinchilla Cochlea1986