Effect of metro train on the critical driving force for preventing smoke back‐layering in tunnel fires
- 27 October 2021
- journal article
- research article
- Published by Wiley in Fire and Materials
- Vol. 46 (6) , 927-942
Abstract
Summary: Preventing smoke back‐layering in longitudinal‐ventilated tunnels is an important topic in handling with fires safety issues. Previous studies focused on the critical velocity, while only very few of them paid attention to how to realize this parameter, that is, in a critical state, to overcome the resistance of the tunnel and the fire source to the airflow, the required driving force provided by the ventilation equipment installed in the tunnel. This study addressed this problem in the situation where the coupling effect of blockage and throttling effect was highlighted by conducting theoretical analysis and numerical simulations. The results showed that the presence of metro train blockage reduces the effective cross‐sectional area of the tunnel near the fire source and decreases the critical velocity. On the other hand, the blockage of trains also increases the resistance to the ventilation airflow and exacerbates the throttling effect, leading to the increase of the critical driving force. In such conditions, a stronger driving force to approach the critical velocity was needed. Besides, the length of train blockage was verified to exert limited influence on the value of critical velocity while it significantly affected the critical driving force. Furthermore, the calculated formula for the critical driving force was proposed with the prevention of smoke back‐layering considering the blockage effect to be emphasized.Keywords
Funding Information
- Chongqing Municipal Science and Technology Bureau (cstc2019jscx‐msxmX0243)
This publication has 54 references indexed in Scilit:
- Effect of blockage-fire distance on buoyancy driven back-layering length and critical velocity in a tunnel: An experimental investigation and global correlationsApplied Thermal Engineering, 2013
- Model scale tunnel fire tests with longitudinal ventilationFire Safety Journal, 2010
- Study of critical velocity and backlayering length in longitudinally ventilated tunnel firesFire Safety Journal, 2010
- Characteristic length scale of critical ventilation velocity in tunnel smoke controlTunnelling and Underground Space Technology, 2010
- Modeling fire-induced smoke spread and carbon monoxide transportation in a long channel: Fire Dynamics Simulator comparisons with measured dataJournal of Hazardous Materials, 2007
- Full-scale burning tests on studying smoke temperature and velocity along a corridorTunnelling and Underground Space Technology, 2005
- DECAY OF BUOYANT SMOKE LAYER TEMPERATURE ALONG THE LONGITUDINAL DIRECTION IN TUNNEL FIRESJournal of Applied Fire Science, 2004
- An Updated International Survey of Computer Models for Fire and SmokeJournal of Fire Protection Engineering, 2003
- Control of smoke flow in tunnel firesFire Safety Journal, 1995
- Interaction Between Duct Fires and Ventilation Flow: An Experimental StudyCombustion Science and Technology, 1979