Abstract
An anatomic surface osteometric analysis of cadaveric cervical spines. To assess the feasibility of placing a 3.5-mm cortical screw in the lateral mass of C1 in a large number of specimens for the purpose of gaining internal fixation for various conditions. Previous studies have addressed surface dimensions of the atlas vertebra and computerized tomography-measured dimensions of the lateral masses of the atlas. These studies used a limited number of specimens with potentially homogeneous origins. A total of 120 atlas (C1) vertebrae for a total of 240 lateral masses were examined and external measurements obtained to assess the feasibility of placing a 3.5-mm cortical screw in the lateral mass. The minimum lateral mass dimensions found from 240 C1 lateral masses were 13.15 mm anterior-posterior, 4.22 mm medial-lateral, and 4.73 mm cephalocaudal. The height of the posterior arch at the groove for the vertebral artery (pedicle analog) was less than 4 mm in 46 of 240 (19.2%) arches. It is feasible to safely and reproducibly place a 3.5-mm cortical screw in the lateral mass of C1 when the appropriate starting point and trajectory of the screw are chosen.

This publication has 16 references indexed in Scilit: