Muscle thickness assessment of the forearm via ultrasonography: is experience level important?
- 1 February 2022
- journal article
- research article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (2) , 027003
Abstract
It is suggested that experience is needed in order to capture valid estimates of muscle size with ultrasound. However, it is unknown whether there is a large degree of skill needed to analyze the images once they are captured. Objective. To determine if less experienced raters could accurately analyze ultrasound images of the forearm by comparing their estimates with those of a very experienced ultrasonographer (criterion). Approach. 50 muscle thickness images were captured by one experienced ultrasonographer (also Rater 1). Those images were saved and were then measured by four raters with different levels of experience. The rater who captured the images was very experienced (criterion), the second rater was also experienced and provided 5 minutes of instruction for Rater 3 (minimal experience) and Rater 4 (no experience). Test-retest reliability was also determined for Rater 3 and 4. Main Results. The average muscle thickness value for the criterion was 3.73 cm. The constant error for Rater 2, 3, and 4 was −0.003 (0.02) cm ( p = 0.362), −0.07 (0.04) cm ( p < 0.001), and 0.02 (0.09) cm ( p = 0.132), respectively. The SD for Rater 4 was greater, resulting in wider limits of agreement compared to Rater 2 and 3. Absolute error was 0.01 cm for Rater 2, whilst it was 0.07 cm and 0.03 cm for the two inexperienced raters (Rater 3 and 4). The error for Rater 3 was systematic and post-hoc assessment found that this rater was using a different border than the other three raters (but consistent across time). For the test-retest reliability, the minimal difference for Rater 3 was 0.08 cm (relative minimal difference of 2%) and 0.17 cm (relative minimal difference of 4%) for Rater 4. Significance. Less experienced raters were able to accurately and reliably analyze already captured muscle thickness images of the forearm with low absolute errors.Keywords
This publication has 15 references indexed in Scilit:
- Inter‐Rater Reliability and Measurement Error of Sonographic Muscle Architecture AssessmentsJournal of Ultrasound in Medicine, 2014
- Ultrasound Is a Reliable Measure of Muscle Thickness in Acute Stroke Patients, for Some, but Not All Anatomical Sites: A Study of the Intra-Rater Reliability of Muscle Thickness Measures in Acute Stroke PatientsUltrasound in Medicine & Biology, 2012
- Ultrasound measures of muscle thickness: intra‐examiner reliability and influence of body positionClinical Physiology and Functional Imaging, 2009
- Intrarater and Interrater Reliability of Assessment of Lumbar Multifidus Muscle Thickness Using Rehabilitative Ultrasound ImagingJournal of Orthopaedic & Sports Physical Therapy, 2007
- Prediction and validation of total and regional skeletal muscle mass by ultrasound in Japanese adultsEuropean Journal of Applied Physiology, 2005
- Skeletal Muscle Cutpoints Associated with Elevated Physical Disability Risk in Older Men and WomenAmerican Journal of Epidemiology, 2004
- Low Relative Skeletal Muscle Mass (Sarcopenia) in Older Persons Is Associated with Functional Impairment and Physical DisabilityJournal of the American Geriatrics Society, 2002
- Leg Muscle Mass and Composition in Relation to Lower Extremity Performance in Men and Women Aged 70 to 79: The Health, Aging and Body Composition StudyJournal of the American Geriatrics Society, 2002
- Real‐time sonography to estimate muscle thickness: Comparison with MRI and CTJournal of Clinical Ultrasound, 2001
- Cadaver validation of skeletal muscle measurement by magnetic resonance imaging and computerized tomographyJournal of Applied Physiology, 1998