A Dosimetric Parameter Reference Look-Up Table for GRID Collimator-Based Spatially Fractionated Radiation Therapy
Open Access
Abstract
Computations of heterogeneity dose parameters in GRID therapy remain challenging in many treatment planning systems (TPS). To address this difficulty, we developed reference dose tables for a standard GRID collimator and validate their accuracy. The .decimal Inc. GRID collimator was implemented within the Eclipse TPS. The accuracy of the dose calculation was confirmed in the commissioning process. Representative sets of simulated ellipsoidal tumours ranging from 6–20 cm in diameter at a 3-cm depth; 16-cm ellipsoidal tumours at 3, 6, and 10 cm in depth were studied. All were treated with 6MV photons to a 20 Gy prescription dose at the tumour center. From these, the GRID therapy dosimetric parameters (previously recommended by the Radiosurgery Society white paper) were derived. Differences in D5 through D95 and EUD between different tumour sizes at the same depth were within 5% of the prescription dose. PVDR from profile measurements at the tumour center differed from D10/D90, but D10/D90 variations for the same tumour depths were within 11%. Three approximation equations were developed for calculating EUDs of different prescription doses for three radiosensitivity levels for 3-cm deep tumours. Dosimetric parameters were consistent and predictable across tumour sizes and depths. Our study results support the use of the developed tables as a reference tool for GRID therapy.Keywords
This publication has 32 references indexed in Scilit:
- The Power of Radiation Biophysics—Let's Use ItInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scanMedical Physics, 2012
- High-Dose Spatially Fractionated GRID Radiation Therapy (SFGRT): A Comparison of Treatment Outcomes With Cerrobend vs. MLC SFGRTInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Evaluation of Spatially Fractionated Radiotherapy (GRID) and Definitive Chemoradiotherapy With Curative Intent for Locally Advanced Squamous Cell Carcinoma of the Head and Neck: Initial Response Rates and ToxicityInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- The Linear-Quadratic Model Is Inappropriate to Model High Dose per Fraction Effects in RadiosurgerySeminars in Radiation Oncology, 2008
- The Linear-Quadratic Model Is an Appropriate Methodology for Determining Isoeffective Doses at Large Doses Per FractionSeminars in Radiation Oncology, 2008
- Elevated sphingomyelinase activity and ceramide concentration in serum of patients undergoing high dose spatially fractionated radiation treatment: Implications for endothelial apoptosisCancer Biology & Therapy, 2005
- Intensity-Modulated Radiation Therapy in Head and Neck CancersAmerican Journal of Clinical Oncology, 2005
- Measurement of the three-dimensional distribution of radiation dose in grid therapyPhysics in Medicine & Biology, 2004
- Dosimetric properties of megavoltage grid therapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1995