Luminescent Pyrene-based Schiff base Receptor for Hazardous Mercury(II) Detection Demonstrated by Cell Imaging and Test Strip
- 30 November 2022
- journal article
- research article
- Published by Springer Nature in Journal of Fluorescence
- Vol. 33 (2) , 539-551
Abstract
Qualitative and quantitative analysis of mercury at concentration levels as low as parts per billion (ppb) is a basic and practical concern. The vast majority of research in this field has centered on the development of potent chemosensor to monitor mercuric (Hg2+) ions. Mercury exists in three oxidation states, + 2, + 1 and 0, all of which are highly poisonous. In this study, (N1E,N2E)-N1,N2-bis(pyrene-1-ylmethylene)benzene-1,2-diamine (PAPM), a novel photoluminescent sensor based on pyrene platform was synthesized. Over the tested metal ions (Cd2+, Co2+, Cu2+, Mg2+, Mn2+, Ni2+, K+, Na+, Zn2+, Sr2+, Pb2+, Al3+, Cr3+ and Fe3+) the sensor responds only to Hg2+ by showing high selectivity and sensitivity. After treatment with mercuric ions at room temperature, the luminescence intensity of probe was quenched at 456 nm. The quenching of fluorescence intensity of probe upon addition of mercury is due to the effect of “turn-off” chelation enhanced quenching (CHEQ) by the formation of 1:1 complex. The ESI–MS spectrum and the Job’s experimental results confirm the formation of 1:1 complex between PAPM and Hg2+. The detection limit and association constant of sensor for mercury is computed using fluorescence titration data and were found to be 9.0 × 10–8 M and 1.29 × 105 M−1 respectively. The practical application of sensor towards recognition of mercury(II) ions was explored through economically viable test strips and also using cell imaging studies.Keywords
This publication has 53 references indexed in Scilit:
- Novel pyrene- and anthracene-based Schiff base derivatives as Cu2+and Fe3+fluorescence turn-on sensors and for aggregation induced emissionsJournal of Materials Chemistry A, 2012
- Synthesis and Characterization of Electroactive Ferrocene Derivatives: Ferrocenylimidazoquinazoline as a Multichannel Chemosensor Selectively for Hg2+ and Pb2+ Ions in an Aqueous EnvironmentInorganic Chemistry, 2011
- Rapid methods to detect organic mercury and total selenium in biological samplesBMC Chemistry, 2011
- Diaza-18-crown-6 appended dual 7-hydroxyquinolines; mercury ion recognition in aqueous solutionChemical Communications, 2008
- A Highly Selective and Sensitive Fluorescent Chemosensor for Hg2+ in Neutral Buffer Aqueous SolutionJournal of the American Chemical Society, 2004
- New Hg2+-Selective Chromo- and Fluoroionophore Based upon 8-HydroxyquinolineThe Journal of Organic Chemistry, 2003
- Determination of Mercury at a Dithizone-Modified Glassy Carbon Electrode by Anodic Stripping VoltammetryAnalytical Sciences, 2002
- Trace Determination of Mercury: A ReviewCritical Reviews in Analytical Chemistry, 1997
- Determination of trace metals in water by neutron activation analysis after preconcentration on a poly(acrylamidoxime) resinAnalytica Chimica Acta, 1991
- Photochemistry of tris(2,2'-bipyridine)ruthenium(2+) ion (Ru(bpy)32+). Solvent effectsJournal of the American Chemical Society, 1983