Reliability and failure modes of narrow implant systems
- 3 November 2015
- journal article
- research article
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 20 (7) , 1505-1513
Abstract
Narrow implants are indicated in areas of limited bone width or when grafting is nonviable. However, the reduction of implant diameter may compromise their performance. This study evaluated the reliability of several narrow implant systems under fatigue, after restored with single-unit crowns. Narrow implant systems were divided (n = 18 each), as follows: Astra (ASC); BioHorizons (BSC); Straumann Roxolid (SNC), Intra-Lock (IMC), and Intra-Lock one-piece abutment (ILO). Maxillary central incisor crowns were cemented and subjected to step-stress accelerated life testing in water. Use level probability Weibull curves and reliability for a mission of 100,000 cycles at 130- and 180-N loads (90 % two-sided confidence intervals) were calculated. Scanning electron microscopy was used for fractography. Reliability for 100,000 cycles at 130 N was ∼99 % in group ASC, ∼99 % in BSC, ∼96 % in SNC, ∼99 % in IMC, and ∼100 % in ILO. At 180 N, reliability of ∼34 % resulted for the ASC group, ∼91 % for BSC, ∼53 % for SNC, ∼70 % for IMC, and ∼99 % for ILO. Abutment screw fracture was the main failure mode for all groups. Reliability was not different between systems for 100,000 cycles at the 130-N load. A significant decrease was observed at the 180-N load for ASC, SNC, and IMC, whereas it was maintained for BSC and ILO. The investigated narrow implants presented mechanical performance under fatigue that suggests their safe use as single crowns in the anterior region.Keywords
This publication has 32 references indexed in Scilit:
- Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: An in vitro laboratory and three-dimensional finite element analysisDental Materials, 2012
- Reliability and failure modes of internal conical dental implant connectionsClinical Oral Implants Research, 2012
- Effect of microthread presence and restoration design (screw versus cemented) in dental implant reliability and failure modesClinical Oral Implants Research, 2012
- Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crownsEuropean Journal of Oral Sciences, 2011
- Implants (3.3 mm Diameter) for the Rehabilitation of Edentulous Posterior Regions: A Retrospective Clinical Study with Up to 11 Years of Follow‐UpClinical Implant Dentistry and Related Research, 2011
- Reliability and Failure Modes of Implant‐Supported Y‐TZP and MCR Three‐Unit BridgesClinical Implant Dentistry and Related Research, 2010
- Fatigue testing of two porcelain–zirconia all-ceramic crown systemsDental Materials, 2009
- Laboratory Simulation of Y-TZP All-ceramic Crown Clinical FailuresJournal of Dental Research, 2009
- Influence of implant/abutment joint designs on abutment screw loosening in a dental implant systemJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2005
- Comparison of the Corrosion Fatigue Characteristics of CP Ti-Grade 4, Ti-6Al-4V ELI, Ti-6Al-7Nb, and Ti-15MoJournal of ASTM International, 2005