Abstract
Developed and validated a simple, robust, chemometric‐assisted, and green, reverse‐phase high‐performance liquid chromatography method for simultaneous quantification of three kinase inhibitors (osimertinib, binimetinib, and erdafitinib) to meet the maximum allowable carryover limits of residues in pharmaceutical cleaning validation. The method was developed on Waters HPLC Alliance e2695 using Xterra RP18 column, simpler mobile phase composition (0.1% formic acid:methanol; 51:49 v/v), detection at 254 nm and 15 min run time with the isocratic mode. Leveraging the analytical quality by design of ICH Q14, the method operable design regions were established by Taguchi screening and Box–Behnken optimization established a, ensuring robustness across chromatographic variables. Replaced acetonitrile with methanol as green solvent to reduce the environmental impact and achieved the analytical greenness metric approach (AGREE) score of 0.72. An assessment was performed for the cross‐contamination risks as per ICH Q3C(R9) for multi‐drug manufacturing (i.e., osimertinib, binimetinib, and erdafitinib) scenario. The method validation parameters performed successfully as per ICH Q2(R2) guideline, which demonstrated a good sensitivity for limit of detection (LOD: 0.5 µg/mL) and quantification (LOQ: 1.0 µg/mL). Considering the real industrial scenario, the recovery of residues performed from different surfaces (stainless steel, glass, and polytetrafluoroethylene plates) using both rinse and swab methods in‐line with the European Medical Agency guideline (1.5 µg/mL as 100% level) to represent the manufacturing of different pharmaceutical products in the shared facilities.Keywords
This publication has 32 references indexed in Scilit:
- Greenness Assessment of High‐Performance Liquid Chromatography Method for Simultaneous Estimation of Apigenin, Apocynin, and Gallic Acid With Quality by Design ApproachSeparation Science Plus, 2025
- Development and Validation of a Stability‐Indicating High‐Performance Liquid Chromatography Method Coupled With a Diode Array Detector for Quantifying Haloperidol in Oral Solution Using the Analytical Quality‐by‐Design ApproachJournal of Separation Science, 2024
- Leveraging Green Chromatography in Quality‐by‐Design‐Driven Study for the Simultaneous Analysis of Essential Single‐Pill Antidiabetic Drug CombinationsJournal of Separation Science, 2024
- A Comprehensive Review of Analytical Methods on Everolimus: A Basis for Cleaning Residue QuantitationSeparation Science Plus, 2024
- Quality by Design‐Assisted RP‐HPLC Method for Determination of Ritonavir and Darunavir in Pharmaceutical Formulation Using Central Composite DesignSeparation Science Plus, 2024
- The combined determinations of multiple veterinary drugs in animal foods by high‐performance liquid chromatography‐diode array detection and their application in drug residue investigationSeparation Science Plus, 2024
- Analytical quality by design approach for the development of high‐performance liquid chromatography method for simultaneous analysis of metformin and sitagliptin in the presence of major degradation productsJournal of Separation Science, 2024
- Separation and characterization of hydrolytic degradation product of deucravacitinib by validated high‐performance liquid chromatography method and liquid chromatography‐mass spectrometrySeparation Science Plus, 2024
- White analytical chemistry‐driven stability‐indicating concomitant chromatographic estimation of thiocolchicoside and aceclofenac using response surface analysis and red, green, and blue modelJournal of Separation Science, 2023
- Quality by design assisted high‐performance liquid chromatography parameters for simultaneous estimation of simvastatin and fenofibrateSeparation Science Plus, 2022