Effect of Ventilator Settings on Mechanical Power During Simulated Mechanical Ventilation of Patients With ARDS
- 27 March 2024
- journal article
- research article
- Published by SAGE Publications in Respiratory Care
- Vol. 69 (4) , 449-462
Abstract
BACKGROUND: In recent years, mechanical power (MP) has emerged as an important concept that can significantly impact outcomes from mechanical ventilation. Several individual components of ventilatory support such as tidal volume (V T ), breathing frequency, and PEEP have been shown to contribute to the extent of MP delivered from a mechanical ventilator to patients in respiratory distress/failure. The aim of this study was to identify which common individual setting of mechanical ventilation is more efficient in maintaining safe and protective levels of MP using different modes of ventilation in simulated subjects with ARDS. METHODS: We used an interactive mathematical model of ventilator output during volume control ventilation (VCV) with either constant inspiratory flow (VCV-CF) or descending ramp inspiratory flow, as well as pressure control ventilation (PCV). MP values were determined for simulated subjects with mild, moderate, and severe ARDS; and whenever MP > 17 J/min, V T , breathing frequency, or PEEP was manipulated independently to bring back MP to ≤ 17 J/min. Finally, the optimum V T -breathing frequency combinations for MP = 17 J/min were determined with all 3 modes of ventilation. RESULTS: VCV-CF always resulted in the lowest MPs while PCV resulted in highest MPs. Reductions in V T were the most efficient for maintaining safer and protective MP. At targeted MPs of 17 J/min and maximized minute ventilation, the optimum V T -breathing frequency combinations were 250–350 mL for V T and 32–35 breaths/min for breathing frequency in mild ARDS, 200–350 mL for V T and 34–40 breaths/min for breathing frequency in moderate ARDS, and 200–300 mL for V T and 37–45 breaths/min for breathing frequency for severe ARDS. CONCLUSIONS: VCV-CF resulted in the lowest MP. V T was the most efficient for maintaining safe and protective MP in a mathematical simulation of subjects with ARDS. In the context of maintaining low and safe MPs, ventilatory strategies with lower-than-normal V T and higher-than-normal breathing frequency will need to be implemented in patients with ARDS.Keywords
This publication has 19 references indexed in Scilit:
- Intra-cycle power: is the flow profile a neglected component of lung protection?Intensive Care Medicine, 2021
- Time-varying intensity of mechanical ventilation and mortality in patients with acute respiratory failure: a registry-based, prospective cohort studyThe Lancet Respiratory Medicine, 2020
- Mechanical power and driving pressure as predictors of mortality among patients with ARDSIntensive Care Medicine, 2020
- Calculation of mechanical power for pressure-controlled ventilationIntensive Care Medicine, 2019
- Ventilator-related causes of lung injury: the mechanical powerIntensive Care Medicine, 2016
- Mechanical Power and Development of Ventilator-induced Lung InjuryAnesthesiology, 2016
- Driving Pressure and Survival in the Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2015
- Low Respiratory Rate Plus Minimally Invasive Extracorporeal Co2 Removal Decreases Systemic and Pulmonary Inflammatory Mediators in Experimental Acute Respiratory Distress Syndrome*Critical Care Medicine, 2014
- Higher versus Lower Positive End-Expiratory Pressures in Patients with the Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2004
- Ventilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2000