Dopant-Assisted Negative Photoionization Ion Mobility Spectrometry for Sensitive Detection of Explosives
- 3 December 2012
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 85 (1) , 319-326
Abstract
Ion mobility spectrometry (IMS) is a key trace detection technique for explosives and the development of a simple, stable, and efficient nonradioactive ionization source is highly demanded. A dopant-assisted negative photoionization (DANP) source has been developed for IMS, which uses a commercial VUV krypton lamp to ionize acetone as the source of electrons to produce negative reactant ions in air. With 20 ppm of acetone as the dopant, a stable current of reactant ions of 1.35 nA was achieved. The reactant ions were identified to be CO3–(H2O)n (K0 = 2.44 cm2 V–1 s–1) by atmospheric pressure time-of-flight mass spectrometry, while the reactant ions in 63Ni source were O2–(H2O)n (K0 = 2.30 cm2 V–1 s–1). Finally, its capabilities for detection of common explosives including ammonium nitrate fuel oil (ANFO), 2,4,6-trinitrotoluene (TNT), N-nitrobis(2-hydroxyethyl)amine dinitrate (DINA), and pentaerythritol tetranitrate (PETN) were evaluated, and the limits of detection of 10 pg (ANFO), 80 pg (TNT), and 100 pg (DINA) with a linear range of 2 orders of magnitude were achieved. The time-of-flight mass spectra obtained with use of DANP source clearly indicated that PETN and DINA can be directly ionized by the ion-association reaction of CO3– to form PETN·CO3– and DINA·CO3– adduct ions, which result in good sensitivity for the DANP source. The excellent stability, good sensitivity, and especially the better separation between the reactant and product ion peaks make the DANP a potential nonradioactive ionization source for IMS.Keywords
This publication has 44 references indexed in Scilit:
- Interfacing an Ion Mobility Spectrometry Based Explosive Trace Detector to a Triple Quadrupole Mass SpectrometerAnalytical Chemistry, 2011
- Photoemission ambient pressure ionization (PAPI) with an ultraviolet light emitting diode and detection of organic compoundsRapid Communications in Mass Spectrometry, 2011
- Modular Ion Mobility Spectrometer for Explosives Detection Using Corona IonizationAnalytical Chemistry, 2011
- Selective Method Based on Negative Electrospray Ionization Ion Mobility Spectrometry for Direct Analysis of Salivary ThiocyanateAnalytical Chemistry, 2010
- Bipolar Ionization Source for Ion Mobility Spectrometry Based on Vacuum Ultraviolet Radiation Induced Photoemission and PhotoionizationAnalytical Chemistry, 2010
- Characterization of a distributed plasma ionization source (DPIS) for ion mobility spectrometry and mass spectrometryTalanta, 2008
- Chemical standards in ion mobility spectrometryAnalytica Chimica Acta, 2003
- Design and optimization of a corona discharge ionization source for ion mobility spectrometryReview of Scientific Instruments, 2000
- Evaluation of gas chromatography coupled with ion mobility spectrometry for monitoring vinyl chloride and other chlorinated and aromatic compounds in air samplesJournal of High Resolution Chromatography, 1996
- Qualitative and quantitative response characteristics of a capillary gas chromatograph/ion mobility spectrometer to halogenated compoundsAnalytica Chimica Acta, 1993