Occupational Exposure to Cobalt: A Population Toxicokinetic Modeling Approach Validated by Field Results Challenges the Biological Exposure Index for Urinary Cobalt
- 10 November 2009
- journal article
- research article
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 7 (1) , 54-62
Abstract
This study modeled the urinary toxicokinetics of cobalt exposure based on 507 urine samples from 16 workers, followed up for 1 week, and 108 related atmospheric cobalt measurements to determine an optimal urinary cobalt sampling strategy at work and a corresponding urinary exposure threshold (UET). These data have been used to calibrate a population toxicokinetic model, taking into account both the measurement uncertainty and intra- and interindividual variability. Using the calibrated model, urinary sampling sensitivity and specificity performance in detecting exposure above the 20 μg/m3 threshold limit value – time-weighted average (TLV-TWA) has been applied to identify an optimal urine sampling time. The UET value is obtained by minimizing misclassification rates in workplace exposures below or above the TLV. Total atmospheric cobalt concentrations are in the 5–144 μg/m3 range, and total urinary cobalt concentrations are 0.5–88 μg/g creatinine. A two-compartment toxicokinetic model best described urinary elimination. Terminal elimination half-time from the central compartment is 10.0 hr (95% confidence interval [8.3–12.3]). The optimal urinary sampling time has been identified as 3 hr before the end of shift at the end of workweek. If we assume that misclassification errors are of equal cost, the UET associated with the TLV of 20 μg/m3 is 5 μg/L, which is lower than the ACGIH-recommended biological exposure index of 15 μg/L. [Supplemental materials are available for this article. Go to the publisher's online edition of the Journal of Occupational and Environmental Hygiene for the following free supplemental resource: an appendix with discussion of the toxicokinetic model, priors, model checking, cross validation, and comparison of ROC curves for various urinary sampling strategy.]Keywords
This publication has 18 references indexed in Scilit:
- Bayesian-Optimal Design via Interacting Particle SystemsJournal of the American Statistical Association, 2006
- Experimental research into the pathogenesis of cobalt/hard metal lung diseaseEuropean Respiratory Journal, 1996
- Biological monitoring of workers exposed to cobalt metal, salt, oxides, and hard metal dust.Occupational and Environmental Medicine, 1994
- Urinary cobalt excretion in short time occupational exposure to cobalt powdersScience of The Total Environment, 1994
- Cobalt determination in serum and urine by electrothermal atomic absorption spectrometryBiological Trace Element Research, 1993
- Inference from Iterative Simulation Using Multiple SequencesStatistical Science, 1992
- AEROSOL EVALUATION DIFFICULTIES DUE TO PARTICLE DEPOSITION ON FILTER HOLDER INNER WALLSAnnals of Occupational Hygiene, 1990
- Respiratory Diseases from Hard Metal or Cobalt ExposureChest, 1989
- Occupational Asthma from Cobalt Sensitivity in Workers Exposed to Hard Metal DustChest, 1989
- Biological monitoring of cobalt exposure, based on cobalt concentrations in blood and urineInternational Archives of Occupational and Environmental Health, 1985