The Accuracy of the Guardian ® RT Continuous Glucose Monitor in Children with Type 1 Diabetes
- 1 August 2008
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 10 (4) , 266-272
Abstract
Objective: The aim of this study was to determine the accuracy of the Guardian ® RT system (Medtronic Minimed, Northridge, CA) in young children and adolescents with type 1 diabetes (T1D) during different scenarios of glucose levels and sensor age. Methods: At five clinical centers, 30 subjects between 4 and 17 years old with T1D were recruited. All subjects had a glycosylated hemoglobin level of ≤10.0% and were using an insulin pump. Subjects initially used a Guardian RT for approximately 1 week at home. Each subject was then hospitalized overnight for about 18 h in a clinical research center, during which time insulin-induced hypoglycemia occurred, along with frequently sampled glucose. Results: There were 1,511 laboratory glucose measurements paired with glucose measurements from 48 Guardian RT sensors. Overall, the median absolute difference (AD) was 21 mg/dL, and the median relative AD (RAD) was 14%, with 64% of sensor values meeting International Organization for Standardization home glucose meter criteria. The median AD was 27 mg/dL for reference glucose values ≤60 mg/dL and 25 mg/dL for reference glucose values ≤70 mg/dL. The median RAD was 19% for reference glucose values 71–120 mg/dL, 14% for reference glucose values 121–180 mg/dL, and 10% for reference glucose values > 180 mg/dL. Conclusions: The Guardian RT appears to perform as well in children with T1D as it has been reported to perform in adults with diabetes. The Guardian RT has an accuracy similar to that of other available continuous glucose monitors and can give important and useful clinical information.Keywords
This publication has 6 references indexed in Scilit:
- Accuracy of the 5-Day FreeStyle Navigator Continuous Glucose Monitoring SystemDiabetes Care, 2007
- The Accuracy of the FreeStyle Navigator Continuous Glucose Monitoring System in Children With Type 1 DiabetesDiabetes Care, 2007
- Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac SurgeryPediatrics, 2006
- Alarms Based on Real-Time Sensor Glucose Values Alert Patients to Hypo- and Hyperglycemia: The Guardian Continuous Monitoring SystemDiabetes Technology & Therapeutics, 2004
- A Multicenter Study of the Accuracy of the One Touch® Ultra® Home Glucose Meter in Children with Type 1 DiabetesDiabetes Technology & Therapeutics, 2003
- Evaluation and comparison of 10 glucose methods and the reference method recommended in the proposed product class standard (1974).Clinical Chemistry, 1977