Expanded Indications for 25-Gauge Transconjunctival Vitrectomy
Authors:
- 28 September 2005
- journal article
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 49 (5) , 397-401
Abstract
We conducted 25-gauge (25G) transconjunctival vitrectomy to treat patients with various ocular diseases, and examined the possibility of expanding the indications for this system through combined use with 20G devices when needed. The records of 167 patients (169 eyes) who underwent vitrectomy in our hospital between April and June 2004 were studied. Vitrectomy had been conducted using the 20G or 25G transconjunctival vitrectomy system. In 7 of the 169 eyes (4%), the 20G system was initially selected. Vitrectomy could be performed using the 25G system alone in 150 eyes (89%), while 20G devices were used in combination with the 25G system in 12 (7%). None of the 25G scleral wounds were sutured, while all the 20G scleral wounds were sutured at the completion of surgery. Low intraocular tension was noted in 15 of 162 eyes (9%), but all these eyes recovered within 2 to 4 days. In two eyes with macular hole, retinal detachment occurred, but reattachment was achieved after reoperation. No extensive vitreoretinal hemorrhage or postoperative infection was observed. By combining the use of 20G devices, indications for the 25G system can be expanded. However, postoperative low ocular tension must be addressed by carefully considering surgical indications and prevention measures. Jpn J Ophthalmol 2005;49:397–401 © Japanese Ophthalmological Society 2005Keywords
This publication has 9 references indexed in Scilit:
- Twenty-gauge Transconjunctival VitrectomyJapanese Journal of Ophthalmology, 2005
- A novel technique for self-sealing, wedge-shaped pars plana sclerotomies and its features in ultrasound biomicroscopy and clinical outcomeAmerican Journal of Ophthalmology, 2003
- OFFICE-BASED SUTURELESS TRANSCONJUNCTIVAL PARS PLANA VITRECTOMYRetina, 2002
- A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch and Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch & Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Modified sutureless sclerotomies in pars plana vitrectomyAmerican Journal of Ophthalmology, 1999
- Complications of Sutureless Pars Plana Vitrectomy Through Self-sealing SclerotomiesArchives of Ophthalmology (1950), 1998
- Sutureless Pars Plana Vitrectomy Through Self-sealing SclerotomiesArchives of Ophthalmology (1950), 1996
- Refinements in Microinstrumentation for Vitreous SurgeryAmerican Journal of Ophthalmology, 1990