Prostate Cancer Detection with Multiparametric Magnetic Resonance Imaging
Open Access
- 20 October 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Chinese Medical Journal
- Vol. 129 (20) , 2451-2459
Abstract
Background: Prostate Imaging Reporting and Data System (PI-RADS) is a globally acceptable standardization for multiparametric magnetic resonance imaging (mp-MRI) in prostate cancer (PCa) diagnosis. The American College of Radiology revised the PI-RADS to address the limitations of version 1 in December 2014. This study aimed to determine whether the PI-RADS version 2 (PI-RADS v2) scoring system improves the diagnostic accuracy of mp-MRI of the prostate compared with PI-RADS v1. Methods: This retrospective study was approved by the institutional review board. A total of 401 consecutive patients, with clinically suspicious PCa undergoing 3.0 T mp-MRI (T2-weighted imaging + diffusion-weighted imaging + DCE) before transrectal ultrasound-guided biopsy between June 2013 and July 2015, were included in the study. All patients were scored using the 5-point PI-RADS scoring system based on either PI-RADS v1 or v2. Receiver operating characteristics were calculated for statistical analysis. Sensitivity, specificity, and diagnostic accuracy were compared using McNemar's test. Results: PCa was present in 150 of 401 (37.41%) patients. When we pooled data from both peripheral zone (PZ) and transition zone (TZ), the areas under the curve were 0.889 for PI-RADS v1 and 0.942 for v2 (P = 0.0001). Maximal accuracy was achieved with a score threshold of 4. At this threshold, in the PZ, similar sensitivity, specificity, and accuracy were achieved with v1 and v2 (all P > 0.05). In the TZ, sensitivity was higher for v2 than for v1 (96.36% vs. 76.36%, P = 0.003), specificity was similar for v2 and v1 (90.24% vs. 84.15%, P = 0.227), and accuracy was higher for v2 than for v1 (92.70% vs. 81.02%, P = 0.002). Conclusions: Both v1 and v2 showed good diagnostic performance for the detection of PCa. However, in the TZ, the performance was better with v2 than with v1.Keywords
This publication has 29 references indexed in Scilit:
- PI-RADS Version 2: A Pictorial UpdateRadioGraphics, 2016
- Prostate Cancer: PI-RADS Version 2 Helps Preoperatively Predict Clinically Significant CancersRadiology, 2016
- PI-RADS Prostate Imaging – Reporting and Data System: 2015, Version 2European Urology, 2016
- Prostate Cancer: Interobserver Agreement and Accuracy with the Revised Prostate Imaging Reporting and Data System at Multiparametric MR ImagingRadiology, 2015
- Prostate Imaging – An UpdateRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2015
- Evaluation of the Prostate Imaging Reporting and Data System for the Detection of Prostate Cancer by the Results of Targeted Biopsy of the ProstateInvestigative Radiology, 2014
- 3-T in-bore MR-guided prostate biopsy based on a scoring system for target lesions characterizationActa Radiologica, 2013
- Prostate Cancer Localization Using Multiparametric MR Imaging: Comparison of Prostate Imaging Reporting and Data System (PI-RADS) and Likert ScalesRadiology, 2013
- Comparison of Interreader Reproducibility of the Prostate Imaging Reporting and Data System and Likert Scales for Evaluation of Multiparametric Prostate MRIAmerican Journal of Roentgenology, 2013
- ESUR prostate MR guidelines 2012European Radiology, 2012