Abstract
This study evaluates the shear bond strength (SBS) of various resin cements to different ceramics. Composite resin cylinders of Z100 were fabricated and cemented to disks of feldspathic ceramic (Creation), leucite-reinforced feldspathic ceramic (Empress I), and densely sintered aluminum oxide ceramic (Procera AllCeram) using five resin cements: Panavia F (PAN), RelyX ARC (ARC), RelyX Unicem (RXU), RelyX Veneer, and Variolink II. SBS was measured after three days of water storage (baseline) and after artificial aging (180 days of water storage along with 12,000 thermal cycles). Failure mode of fractured specimens also was evaluated. Data were analyzed with Kruskal-Wallis and Mann-Whitney tests (α=0.05). RXU showed 1) the lowest baseline median SBS to feldspathic ceramic, which was not statistically different from PAN; 2) the lowest median baseline SBS to leucite-reinforced feldspathic and densely sintered aluminum-oxide ceramics. All cements performed similarly after aging, except for ARC (median 0.0 MPa) and PAN (median 16.2 MPa) in the densely sintered aluminum-oxide ceramic group. Resin cements perform differently when bonded to different ceramic substrates. While all test resin cements worked similarly in the long-term to feldspathic and leucite-reinforced feldspathic ceramics, only the MDP-containing resin cement provided durable bonds to densely sintered aluminum-oxide ceramic.Keywords
This publication has 34 references indexed in Scilit:
- The effect of nano-structured alumina coating on resin-bond strength to zirconia ceramicsDental Materials, 2010
- Comparison of resin cement adhesion to Y-TZP ceramic following manufacturers’ instructions of the cements onlyClinical Oral Investigations, 2007
- Bond Durability of Composite Luting Agents to Ceramic When Exposed to Long-term ThermocyclingOperative Dentistry, 2007
- Chemical analysis and bonding reaction of RelyX Unicem and Bifix composites—A comparative studyDental Materials, 2006
- Microtensile bond strength of a resin cement to glass infiltrated zirconia-reinforced ceramic: The effect of surface conditioningDental Materials, 2006
- Shear bond strength of composite resin cements to lithium disilicate ceramicsJournal of Oral Rehabilitation, 2005
- Effects of surface treatments on shear bond strengths between a resin cement and an alumina coreThe Journal of Prosthetic Dentistry, 2000
- Bonding of resin cements to an aluminous ceramic: A new surface treatmentDental Materials, 1994
- Porcelain-composite interface microleakage with various porcelain surface treatmentsDental Materials, 1991
- Influence of Silane Treatment and Filler Fraction on Thermal Expansion of Composite ResinsJournal of Dental Research, 1984