Performance evaluation of quantitative material decomposition in slow kVp switching dual-energy CT
- 30 December 2023
- journal article
- research article
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 32 (1) , 69-85
Abstract
BACKGROUND: Slow kVp switching technique is an important approach to realize dual-energy CT (DECT) imaging, but its performance has not been thoroughly investigated yet. OBJECTIVE: This study aims at comparing and evaluating the DECT imaging performance of different slow kVp switching protocols, and thus helps determining the optimal system settings. METHODS: To investigate the impact of energy separation, two different beam filtration schemes are compared: the stationary beam filtration and dynamic beam filtration. Moreover, uniform tube voltage modulation and weighted tube voltage modulation are compared along with various modulation frequencies. A model-based direct decomposition algorithm is employed to generate the water and iodine material bases. Both numerical and physical experiments are conducted to verify the slow kVp switching DECT imaging performance. RESULTS: Numerical and experimental results demonstrate that the material decomposition is less sensitive to beam filtration, voltage modulation type and modulation frequency. As a result, robust material-specific quantitative decomposition can be achieved in slow kVp switching DECT imaging. CONCLUSIONS: Quantitative DECT imaging can be implemented with slow kVp switching under a variety of system settings.Keywords
This publication has 29 references indexed in Scilit:
- Multi-Material Decomposition Using Statistical Image Reconstruction for Spectral CTIEEE Transactions on Medical Imaging, 2014
- Dual-Energy CT: General PrinciplesAmerican Journal of Roentgenology, 2012
- Dual-Energy Dual-Source CT With Additional Spectral Filtration Can Improve the Differentiation of Non–Uric Acid Renal Stones: An Ex Vivo Phantom StudyAmerican Journal of Roentgenology, 2011
- Dual energy CT using slow kVp switching acquisition and prior image constrained compressed sensingPhysics in Medicine & Biology, 2010
- SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubesPhysics in Medicine & Biology, 2009
- Improved dual‐energy material discrimination for dual‐source CT by means of additional spectral filtrationMedical Physics, 2009
- Technical principles of dual source CTEuropean Journal of Radiology, 2008
- Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data setsMedical Physics, 2008
- Split-Filter Computed TomographyJournal of Computer Assisted Tomography, 1980
- Energy-selective reconstructions in X-ray computerised tomographyPhysics in Medicine & Biology, 1976