Transmission-Line Anti-Reflection Coating for High-Frequency Ultrasound IC Inspection
- 20 March 2026
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-7
Abstract
High-frequency ultrasound imaging, due to its penetrability and micron-level resolution, is a critical modality for non-destructive testing (NDT) of integrated circuit (IC) packaging. However, the substantial acoustic impedance mismatch between the coupling medium (water) and the silicon substrate creates a severe measurement bottleneck: strong surface reflections drastically reduce the energy transmitted into the chip, degrading the signal-to-noise ratio (SNR) and resolution of internal interconnects. To overcome this physical limitation and enhance the measurement capability of scanning acoustic microscopy (SAM), we have designed a precise anti-reflection coating based on the theory of the evolution from electromagnetic transmission lines to acoustic transmission lines. By modeling the acoustic propagation path as an equivalent circuit, we designed and fabricated a three-layer composite structure (Parylene C/Au/Parylene C) specifically optimized for the particular frequency (70 MHz in this study). Experimental validation on commercial IC chips demonstrates that this "instrumentation conditioning" approach significantly improves signal integrity. Specifically, the coating yielded a 52% increase in the amplitude of internal echoes (from 142 mV to 216 mV). Furthermore, C-scan imaging revealed a 93% average improvement in the mean gradient of internal metal wires across multiple layers, enabling high-fidelity 3D reconstruction of interconnection structures that were previously indistinguishable from noise. This method offers a robust, low-cost solution to the intrinsic attenuation problem in high-frequency acoustic measurement, significantly extending the detection depth and clarity for IC reliability analysis.Keywords
Funding Information
- National Natural Science Foundation of China (62474129)
- National Natural Science Foundation of China (52402154)
- Shaanxi Sanqin Talent Special Support Program: Young Top-notch Talent Project
- Xidian University Interdisciplinary Expansion Special Support Program: Frontier Basic Research Project
This publication has 26 references indexed in Scilit:
- Multi-layer polymer-metal structures for acoustic impedance matching in high-frequency broadband ultrasonic transducers designApplied Acoustics, 2020
- High-resolution non-destructive three-dimensional imaging of integrated circuitsNature, 2017
- Ultrahigh Frequency (100 MHz–300 MHz) Ultrasonic Transducers for Optical Resolution Medical ImaginingScientific Reports, 2016
- Design of matching layers for high-frequency ultrasonic transducersApplied Physics Letters, 2015
- An overview of scanning acoustic microscope, a reliable method for non-destructive failure analysis of microelectronic components2015
- An acoustic filter based on layered structureApplied Physics Letters, 2015
- NDI of delamination in IC packages using millimeter-wavesIEEE Transactions on Instrumentation and Measurement, 2001
- Scanning acoustic microscopyUltrasonics, 1993
- A nondestructive diagnostic method based on swept-frequency ultrasound transmission-reflection measurementsIEEE Transactions on Instrumentation and Measurement, 1992