Reproducibility of Electromagnetic Field Simulations of Local Radiofrequency Transmit Elements Tailored for 7 T MRI
Authors:
- Max Joris HubmannMHMax Joris Hubmann
- Bilguun NurzedBNBilguun Nurzed
- Sam-Luca HansenSHSam-Luca Hansen
- Robert KowalRKRobert Kowal
- Natalie SchönNSNatalie Schön
- Daniel WenzDWDaniel Wenz
- Nandita SahaNandita Saha
- Max LutzMLMax Lutz
- Thomas M. FiedlerTFThomas M. Fiedler
- Stephan OrzadaSOStephan Orzada
- Lukas WinterLWLukas Winter
- Boris KeilBKBoris Keil
Open Access
Abstract
The literature reports on radiofrequency (RF) transmit (Tx) elements tailored for ultrahigh-field (UHF) magnetic resonance imaging (MRI) showed confounded reproducibility due to variations in simulation tools, modeling assumptions, and meshing techniques. This study proposes a standardized methodology to improve reproducibility and consistency across research sites (testers) and simulation tools (testing conditions). The methodology includes detailed simulation workflow and performance metrics for RF Tx elements. The impact of the used mesh setting is assessed. Following the methodology, a reproducibility study was conducted using CST Microwave Studio Suite, HFSS, and Sim4Life. The methodology and simulations were ultimately validated through 7 T MRI phantom experiments. The reproducibility study showed consistent performance with less than 6% standard deviation for B1+ fields and 12% for peak SAR averaged over 10 g tissue (pSAR10g). The SAR efficiency metric (|B1+|/√pSAR10g) was particularly robust (B1+| maps showed good qualitative agreement. This study demonstrates the feasibility of a standardized methodology for achieving reproducible RF Tx element electromagnetic field simulations. By following the FAIR principles including making the framework publicly available, we promote transparency and collaboration within the MRI community, supporting the advancement of technological innovation and improving patient safety in UHF-MRI.Keywords
Funding Information
- European Research Council (743077, SCHM 2677/2-1, SCHM 2677/4-1, 13GW0473A, ZS/2019/02/97145, ZS/2023/12/182010, ZS/2023/12/182179, 21NRM05 STASIS)
- iNAMES—MDC-Weizmann Helmholtz International Research School for Imaging and Data Science from the NAno to the MESo (743077, SCHM 2677/2-1, SCHM 2677/4-1, 13GW0473A, ZS/2019/02/97145, ZS/2023/12/182010, ZS/2023/12/182179, 21NRM05 STASIS)
- Deutsche Forschungsgemeinschaft (743077, SCHM 2677/2-1, SCHM 2677/4-1, 13GW0473A, ZS/2019/02/97145, ZS/2023/12/182010, ZS/2023/12/182179, 21NRM05 STASIS)
- Bundesministerium für Forschung, Technologie und Raumfahrt (743077, SCHM 2677/2-1, SCHM 2677/4-1, 13GW0473A, ZS/2019/02/97145, ZS/2023/12/182010, ZS/2023/12/182179, 21NRM05 STASIS)
- European Regional Development Fund (743077, SCHM 2677/2-1, SCHM 2677/4-1, 13GW0473A, ZS/2019/02/97145, ZS/2023/12/182010, ZS/2023/12/182179, 21NRM05 STASIS)
- European Partnership of Metrology (743077, SCHM 2677/2-1, SCHM 2677/4-1, 13GW0473A, ZS/2019/02/97145, ZS/2023/12/182010, ZS/2023/12/182179, 21NRM05 STASIS)
This publication has 45 references indexed in Scilit:
- A multitransmit external body array combined with a 1H and 31P endorectal coil to enable a multiparametric and multimetabolic MRI examination of the prostate at 7TMedical Physics, 2019
- Approaching ultimate intrinsic signal‐to‐noise ratio with loop and dipole antennasMagnetic Resonance in Medicine, 2017
- Parallel transmit capability of various RF transmit elements and arrays at 7T MRIMagnetic Resonance in Medicine, 2017
- A 16‐channel combined loop‐dipole transceiver array for 7 Tesla body MRIMagnetic Resonance in Medicine, 2016
- The fractionated dipole antenna: A new antenna for body imaging at 7 TeslaMagnetic Resonance in Medicine, 2015
- Signal‐to‐noise ratio and MR tissue parameters in human brain imaging at 3, 7, and 9.4 tesla using current receive coil arraysMagnetic Resonance in Medicine, 2015
- MRI at 7 tesla and above: Demonstrated and potential capabilitiesJournal of Magnetic Resonance Imaging, 2014
- Modular 32-channel transceiver coil array for cardiac MRI at 7.0TMagnetic Resonance in Medicine, 2013
- Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency fieldMagnetic Resonance in Medicine, 2006
- Signal‐to‐noise ratio and absorbed power as functions of main magnetic field strength, and definition of “90°” RF pulse for the head in the birdcage coilMagnetic Resonance in Medicine, 2001