Computer Navigation and Total Knee Arthroplasty
Authors:
- Jingsheng ShiJSJingsheng Shi
- Yibing WeiYWYibing Wei
- Siqun WangSWSiqun Wang
- Feiyan ChenFCFeiyan Chen
- Jianguo WuJWJianguo Wu
- Gangyong HuangGHGangyong Huang
- Jie ChenJCJie Chen
- Licheng WeiLWLicheng Wei
- Jun XiaJXJun Xia
- 1 January 2014
- journal article
- research article
- Published by SLACK, Inc. in Orthopedics
- Vol. 37 (1) , e39-e43
Abstract
Research has added evidence in favor of computer-navigated techniques over conventional surgery for total knee arthroplasty (TKA). The goal of the current meta-analysis was to compare the outcome of outliers in mechanical axis and postoperative complications in patients undergoing conventional vs computer-navigated techniques for TKA. English literature searches were performed in PubMed, EMBASE, Web of Science, and the Cochrane Library for studies published between January 2002 and August 2012. Randomized, controlled trials comparing computer navigation with conventional surgery for the measurement of mechanical axes in patients with primary osteoarthritis were considered eligible. Fifteen trials were eligible for inclusion. The baseline demographics of 2089 patients (computer-navigated=1111; conventional=978) were well matched. Publication bias was eliminated using the funnel plot. A mechanical axis of more than 30° was considered to be malalignment and an outlier in limb alignment. A significant increase of 16.9 minutes in mean operative time for computer-navigated TKA was observed ( P =.046). Although patients undergoing computer-navigated TKA had fewer outliers in mechanical axis (13.4%) compared with the conventional technique (27.4%), the results did not achieve statistical significance (I 2 =0.0%; P =1.000). Fewer complications were observed in patients undergoing computer-navigated TKA (4%) compared with conventional TKA (6.5%). The use of computer-navigated TKA reduced the number of outliers in mechanical axis compared with conventional TKA; however, it did not achieve statistical significance. Additional research with longer follow-up is recommended.Keywords
This publication has 24 references indexed in Scilit:
- Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studiesInternational Orthopaedics, 2010
- Computer assisted versus conventional cemented total knee prostheses alignment accuracy and micromotion of the tibial componentInternational Orthopaedics, 2008
- Meta-Analysis of Alignment Outcomes in Computer-Assisted Total Knee Arthroplasty SurgeryThe Journal of Arthroplasty, 2007
- Comparison of Limb and Component Alignment Using Computer-Assisted Navigation Versus Image Intensifier–Guided Conventional Total Knee ArthroplastyThe Journal of Arthroplasty, 2007
- Imageless Navigation for TKA Increases Implantation AccuracyClinical Orthopaedics and Related Research, 2007
- Alignments and Clinical Results in Conventional and Navigated Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2007
- Navigation in total knee arthroplasty. A multicenter studyInternational Orthopaedics, 2006
- Computer-assisted knee arthroplasty versus a conventional jig-based techniqueThe Journal of Bone and Joint Surgery. British volume, 2004
- Navigation in der Knieendoprothetik - vorläufige klinische Erfahrungen und prospektiv vergleichende Studie gegenüber konventioneller lmplantationstechnikZeitschrift für Orthopädie und ihre Grenzgebiete, 2001
- Alignment in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1983