Modified Short-Axis Out-of-Plane Ultrasound Versus Conventional Long-Axis In-Plane Ultrasound to Guide Radial Artery Cannulation
Authors:
- Ming TianMTMing Tian
- Ping ChiPCPing Chi
- YingHao CaoYCYingHao Cao
- Xin LiXLXin Li
- KeJun PengKPKeJun Peng
- 1 July 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 119 (1) , 163-169
Abstract
Currently, short-axis out-of-plane (SA-OOP) and long-axis in-plane (LA-IP) ultrasound techniques are used to guide radial artery cannulation. In this study, we compared the success rate of a modified SA-OOP technique with that of traditional LA-IP. One hundred sixty-four patients who were to undergo liver surgery or splenic resection under general anesthesia were included. Using a sealed envelope method, patients were randomly divided into 2 groups: the modified SA-OOP or the LA-IP ultrasound guidance approaches. The number of cannula insertion attempts until success was recorded in both groups. The primary end point to compare the groups was the rate of cannula insertion successes on the first attempt. The secondary end points were also recorded and compared: insertion failure rate, inner diameter of the radial artery, depth of artery from the skin, ultrasonic location time, cannulation time, and vascular complications including thrombosis, hematoma, edema, and vasospasm. The cannula insertion success rate on the first attempt was significantly higher in the modified SA-OOP group compared with the LA-IP group (proportion difference 15.7%, 95% confidence interval [CI], 0.6%-30.7%, P = 0.0158). However, the insertion failure rate was not different between groups (95% CI, -17.7% to 12.8%, P = 0.4969). The ultrasonic location time was significantly decreased in the modified SA-OOP group compared with the LA-IP group (mean difference -9.5 seconds, 95% CI, -10.6 to -8.5 seconds, P < 0.0001). However, there was no significant difference between groups for cannulation time (95% CI, -0.6 to 7.6 seconds, P = 0.1152), depth of artery (95% CI, -0.07 to 0.57 mm, P = 0.1050), and the diameter of the radial artery (95% CI, -0.30 to 0.03 mm, P = 0.1153). The modified SA-OOP technique may improve the success rate of cannula insertion into the radial artery on the first attempt.Keywords
This publication has 12 references indexed in Scilit:
- Imaging and management of complications of central venous cathetersClinical Radiology, 2013
- A comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulationThe American Journal of Emergency Medicine, 2013
- High‐frequency micro‐ultrasound for vascular access in young children – a feasibility study by the High‐frequency UltraSound in Kids studY (HUSKY) groupPediatric Anesthesia, 2013
- Ultrasound visual image-guided vs Doppler auditory-assisted radial artery cannulation in infants and small children by non-expert anaesthesiologists: a randomized prospective studyBritish Journal of Anaesthesia, 2013
- Needle tip visualization during ultrasound-guided vascular access: short-axis vs long-axis approachThe American Journal of Emergency Medicine, 2010
- Radial Artery Cannulation: A Comprehensive Review of Recent Anatomic and Physiologic InvestigationsAnesthesia & Analgesia, 2009
- Ultrasound-guided central venous catheter placement decreases complications and decreases placement attempts compared with the landmark technique in patients in a pediatric intensive care unit*Critical Care Medicine, 2009
- Use of ultrasonography as a rescue technique for failed radial artery cannulationJournal of Clinical Anesthesia, 2006
- Ultrasound Guidance versus the Landmark Technique for the Placement of Central Venous Catheters in the Emergency DepartmentAcademic Emergency Medicine, 2002
- Ultrasound Guidance versus the Landmark Technique for the Placement of Central Venous Catheters in the Emergency DepartmentAcademic Emergency Medicine, 2002