Abstract
Background Stereoelectroencephalography (SEEG) is an established diagnostic technique for the localization of the epileptogenic zone in drug-resistant epilepsy. In vivo accuracy of SEEG electrode positioning is of paramount importance since higher accuracy may lead to more precise resective surgery, better seizure outcome and reduction of complications. Objective To describe experiences with the SEEG technique in our comprehensive epilepsy center, to illustrate surgical methodology, to evaluate in vivo application accuracy and to consider the diagnostic yield of SEEG implantations. Methods All patients who underwent SEEG implantations between September 2008 and April 2016 were analyzed. Planned electrode trajectories were compared with post-implantation trajectories after fusion of pre- and postoperative imaging. Quantitative analysis of deviation using Euclidean distance and directional errors was performed. Explanatory variables for electrode accuracy were analyzed using linear regression modeling. The surgical methodology, procedure-related complications and diagnostic yield were reported. Results Seventy-six implantations were performed in 71 patients, and a total of 902 electrodes were implanted. Median entry and target point deviations were 1.54 mm and 2.93 mm. Several factors that predicted entry and target point accuracy were identified. The rate of major complications was 2.6%. SEEG led to surgical therapy of various modalities in 53 patients (69.7%). Conclusions This study demonstrated that entry and target point localization errors can be predicted by linear regression models, which can aid in identification of high-risk electrode trajectories and further enhancement of accuracy. SEEG is a reliable technique, as demonstrated by the high accuracy of conventional frame-based implantation methodology and the good diagnostic yield.Keywords
Funding Information
- Maastricht University Medical Center (UMC+)
This publication has 88 references indexed in Scilit:
- Stereoelectroencephalography in the “difficult to localize” refractory focal epilepsy: Early experience from a North American epilepsy centerEpilepsia, 2012
- Is MRI a reliable tool to locate the electrode after deep brain stimulation surgery? Comparison study of CT and MRI for the localization of electrodes after DBSActa Neurochirurgica, 2010
- Stereotactic electroencephalography with temporal grid and mesial temporal depth electrode coverage: does technique of depth electrode placement affect outcome?Journal of Neurosurgery, 2010
- Clinical Accuracy of a Customized Stereotactic Platform for Deep Brain Stimulation after Accounting for Brain ShiftStereotactic and Functional Neurosurgery, 2010
- Accuracy and Distortion of Deep Brain Stimulation Electrodes on Postoperative MRI and CTCentral European Neurosurgery, 2008
- Surgical Complications of Epilepsy Surgery Procedures : Experience of 179 Procedures in a Single InstituteJournal of Korean Neurosurgical Society, 2008
- Stereoelectroencephalography in the presurgical evaluation of children with drug-resistant focal epilepsyJournal of neurosurgery. Pediatrics, 2005
- Neurophysiological Monitoring for Epilepsy Surgery: The Talairach SEEG MethodStereotactic and Functional Neurosurgery, 2001
- Patients with Refractory SeizuresNew England Journal of Medicine, 1999