Cross-Linked Versus Conventional Polyethylene for Long-Term Clinical Outcomes After Total Hip Arthroplasty: A Systematic Review and Meta-Analysis
- 2 July 2019
- journal article
- review article
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 34 (3) , 307-317
Abstract
Background: Cross-linked polyethylene (HXLPE) liners have been used for total hip arthroplasty (THA) to address the problem of osteolysis and revision surgery associated with conventional polyethylene (CPE) liners. This systematic review and meta-analysis investigated the long-term efficacy of HXLPE in preventing revision surgery and radiological osteolysis in comparison to CPE. Materials and Methods: A comprehensive search of PubMed, Embase, and the Cochrane Library from their respective inception to September 2018 was conducted to identify potential candidate articles. Data were pooled using Stata software 14.0. The quality of randomized controlled trials (RCTs) and observational studies was assessed by two different authors using the Cochrane risk-of-bias tool and the Newcastle–Ottawa scale (NOS), respectively. Results: Eight RCTs and six observational studies were included in this review. The pooled results significantly favored HXLPE over CPE in terms of total number of revisions and radiological osteolysis, with a risk reduction of 78% (95% confidence interval [CI] 0.13–0.36; p < 0.001) and 80% (95% CI 0.13–0.29; p < 0.001), respectively. Additionally, subgroup analyses of pooled data from RCTs and observational studies both showed the efficacy of HXLPE in the prevention of revision and osteolysis. Polyethylene wear in the HXLPE group was significantly less than that in the CPE group in terms of linear wear rates and head penetration rates (both p < 0.001). No significant differences were observed with regard to functional outcomes. Conclusions: The current evidence shows that HXLPE significantly improved the clinical and radiographic outcomes, but not the functional outcomes, in comparison to CPE in long-term follow-up.Keywords
Funding Information
- Talented Scientists (SRF (2009) 149)
This publication has 36 references indexed in Scilit:
- Cementless THA for the Treatment of Osteonecrosis at 10-Year Follow-Up: Have We Improved Compared to Cemented THA?The Journal of Arthroplasty, 2013
- History and Systematic Review of Wear and Osteolysis Outcomes for First-generation Highly Crosslinked PolyethyleneClinical Orthopaedics and Related Research, 2011
- The Incidence of Acetabular Osteolysis in Young Patients With Conventional versus Highly Crosslinked PolyethyleneClinical Orthopaedics and Related Research, 2011
- Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analysesEuropean Journal of Epidemiology, 2010
- A systematic review of radiological outcomes of highly cross-linked polyethylene versus conventional polyethylene in total hip arthroplastyInternational Orthopaedics, 2009
- Wear particle analysis of highly crosslinked polyethylene isolated from a failed total hip arthroplastyJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2008
- The Cochrane Collaboration: A leading role in producing reliable evidence to inform healthcare decisions in musculoskeletal trauma and disordersIndian Journal of Orthopaedics, 2008
- The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particlesBiomaterials, 2004
- Interpretation of observational studies: Figure 1Heart, 2004
- The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic‐grade polyethyleneJournal of Biomedical Materials Research Part A, 2003