The Accuracy of Navigation and 3D Image-Guided Placement for the Placement of Pedicle Screws in Congenital Spine Deformity
- 1 September 2012
- journal article
- spine
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 32 (6) , e23-e29
Abstract
Background: Treatment of congenital spine deformity has high surgical risk due to abnormal anatomy and dysmorphic pedicles. We hypothesized that an image-guided navigation system would result in a low rate of screw revision due to malposition. Methods: From 2007 to 2010, 142 screws were placed in 14 consecutive patients with congenital spine deformity using an intraoperative computer tomography (CT) (O-arm) and image-guided navigation system (Stealth). Mean age was 8.8 years (range, 1 to 18 y). Deformities included scoliosis (12), kyphosis (1), and spinal dysgenesis (1). Screws were placed from T2 to S1. An intraoperative CT verified screw position. Need for intraoperative screw revision is the primary outcome measure. Results: Of the 142 screws placed, 1 required revision intraoperatively due to malposition (99.3% screw accuracy rate). The screw was at L3 and was successfully redirected. There were no complications due to screw malposition. This navigated congenital screw accuracy rate (99.3%) is higher than the 94.9% accuracy rate reported for non-navigated screws in all children undergoing pedicle screw fixation in a recent systematic literature review and higher than the reported 96.4% accuracy rate for navigated pedicle screws in children. Kosmopoulos and colleagues found a lower accuracy rate (86.6%) in adult non-navigated screws (P<0.0001) and adult navigated screws (93.7%). Of note, 9 pedicles were noted on navigation to be absent. Despite the goal of bilateral screw placement at each fusion level, 31 of 173 pedicles were left unfilled due to technical impossibility based on intraoperative CT imaging. This represents an 18% screw dropout rate. Conclusions: CT-guided navigation resulted in the successful placement of 142 pedicle screws in patients with congenital deformity and altered anatomy, which represents a 99.3% screw accuracy rate. This is comparable with the screw accuracy rate of 93.7% reported for adult navigated pedicle screws. Further, navigation prevented attempts of screw placement at levels with absent or impassable pedicles. Image-guided navigation and intraoperative CT are valuable tools for the safe placement of pedicle screws in patients with significant congenital spine deformity and altered anatomy. Level of Evidence: IV, Case Series.Keywords
This publication has 24 references indexed in Scilit:
- The Safe Placement of Upper and Middle Thoracic Pedicle Screws in Pediatric DeformityJournal of Spinal Disorders & Techniques, 2011
- Isolated Pedicle Screw Instrumented Correction for the Treatment of Thoracic Congenital ScoliosisJournal of Spinal Disorders & Techniques, 2010
- Instrumentation and Fusion for Congenital Spine DeformitiesSpine, 2009
- Hemivertebra Resection and Osteotomies in Congenital Spine DeformitySpine, 2009
- Classification of Congenital Scoliosis and KyphosisSpine, 2009
- Safety and Efficacy of Posterior Instrumentation for Patients With Congenital Scoliosis and Spinal DysraphismJournal of Pediatric Orthopaedics, 2007
- Management Themes in Congenital ScoliosisJournal of Bone and Joint Surgery, 2007
- Posterior Hemivertebra Resection With Transpedicular Instrumentation: Early Correction in Children Aged 1 to 6 YearsSpine, 2003
- Hemivertebra Resection by a Posterior ApproachSpine, 2002
- One-Stage Posterior Hemivertebra Resection and Correction Using Segmental Posterior InstrumentationSpine, 2001