Performance of high conformability vs . high radial force devices in the virtual treatment of TAVI patients with bicuspid aortic valve
- 5 February 2021
- journal article
- research article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 89 (1) , 42-50
Abstract
Transcatheter Aortic Valve Implantation (TAVI) is a consolidated procedure showing a low operative risk and excellent long-term outcomes in patients with aortic stenosis. Patients presenting a bicuspid aortic valve (BAV) often require valve replacement due to the highly calcific nature of the aortic leaflets. However, BAV patients have usually been contraindicated for TAVI due to their complex valve anatomy. The aim of this work was to compare the performance of devices featuring high conformability (HC) against those with high radial force (HRF). Four BAV patients undergoing TAVI were retrospectively selected. The aortic roots including the native leaflets and calcifications were reconstructed from pre-operative Computed Tomography scans. In each patient, both HC and HRF devices were virtually implanted using Finite Element Analysis simulations. After implantation, paravalvular orifice area, von Mises stress distribution, root contact area, and device eccentricity were calculated. Simulations showed good agreement with intraoperative imaging. In 3 out of 4 patients, the HRF device resulted in a lower paravalvular area than the HC. Stress distribution was also more homogeneously distributed in the HRF group as compared with the HC group. Despite their lower adaptability, HRF devices showed consistently higher stent-root contact area. HRF devices showed improved results with respect to HC valves after being deployed in BAV anatomies. We hypothesize that the ability to reshape the annulus is the major determinant of success in this subgroup of patients featuring highly calcified leaflets.Keywords
This publication has 25 references indexed in Scilit:
- Prediction of patient-specific post-operative outcomes of TAVI procedure: The impact of the positioning strategy on valve performanceJournal of Biomechanics, 2016
- Aortic annulus eccentricity before and after transcatheter aortic valve implantation: Comparison of balloon-expandable and self-expanding prosthesesEuropean Journal of Radiology, 2015
- Transcatheter Aortic Valve Implantation (TAVI) in Patients With Bicuspid Aortic Valve Stenosis – Systematic Review and Meta-AnalysisHeart, Lung and Circulation, 2015
- Prognostic influence of paravalvular leak following TAVI: is aortic regurgitation an active incremental risk factor or just a mere indicator?European Heart Journal, 2014
- Simulation of transcatheter aortic valve implantation through patient-specific finite element analysis: Two clinical casesJournal of Biomechanics, 2014
- Significant differences in the material properties between aged human and porcine aortic tissuesEuropean Journal of Cardio-Thoracic Surgery, 2011
- Anatomic and Procedural Predictors of Paravalvular Aortic Regurgitation After Implantation of the Medtronic CoreValve BioprosthesisJACC, 2010
- Geometry and Degree of Apposition of the CoreValve ReValving System With Multislice Computed Tomography After Implantation in Patients With Aortic StenosisJACC, 2009
- A classification system for the bicuspid aortic valve from 304 surgical specimensThe Journal of Thoracic and Cardiovascular Surgery, 2007
- Shape-memory alloys: modelling and numerical simulations of the finite-strain superelastic behaviorComputer Methods in Applied Mechanics and Engineering, 1997