Investigation of the appropriate viscosity of fibrinogen in repairing pleural defects using ventilation and anchoring in an ex vivo pig model
Preprint
- 25 September 2023
- preprint
- Published by Springer Nature in Research Square
Abstract
Objective Our previous study revealed that the viscosity of fibrinogen could influence the effectiveness of ventilation and anchoring (V/A) methods for controlling air leakages. Here, we examined the association between the viscosity of fibrinogen and effectiveness using an ex vivo pig model. Methods The fibrin glue used in this study was BOLHEAL® (KM Biologics Co., Ltd., Kumamoto, Japan). We prepared three types of fibrinogen with different viscosities (higher and lower than normal), including one without additives. Using an ex vivo pig model, a pleural defect was made, and the defect was repaired using three different viscosities of fibrinogen through the V/A method. We measured the rupture pressure at the repair site (N=10) and histologically evaluated the depth of fibrin infiltration into the lung parenchyma at the repair sites. Results The median rupture pressure was 51.5 (40–73) cmH2O in Group 1 (lower viscosity), 47.0 (47–88) cmH2O in Group 2 (no change in viscosity), and 35.5 (25¬–61) cmH2O in Group 3 (higher viscosity). There was no statistically significant difference between Groups 1 and 2 (p = 0.819), but the rupture pressure was significantly higher in Group 2 than in Group 3 (p = 0.0136). Histological evaluation revealed deep infiltration of fibrin into the lung parenchyma in Groups 1 and 2, but no such infiltration was observed in the higher-viscosity group. Conclusions The results of this experiment suggested that the V/A method using fibrin glue containing low-viscosity fibrinogen was more effective in controlling air leakage due to pleural defects.Keywords
All Related Versions
This publication has 20 references indexed in Scilit:
- Propensity matched comparison of extrapleural pneumonectomy and pleurectomy/decortication for mesothelioma patients†Interactive CardioVascular and Thoracic Surgery, 2017
- Experimental Study on the Viscosity and Adhesive Performance of Exogenous Liquid Fibrin GlueNeurologia medico-chirurgica, 2014
- Investigation of the freely available easy-to-use software ‘EZR’ for medical statisticsBone Marrow Transplantation, 2012
- Pleurectomy/Decortication is Superior to Extrapleural Pneumonectomy in the Multimodality Management of Patients with Malignant Pleural MesotheliomaJournal of Thoracic Oncology, 2012
- A Unique Method for Repairing Intraoperative Pulmonary Air Leakage with Both Polyglycolic Acid Sheets and Fibrin GlueWorld Journal of Surgery, 2011
- Survival after trimodality therapy for malignant pleural mesothelioma: Radical Pleurectomy, chemotherapy with Cisplatin/Pemetrexed and radiotherapyLung Cancer, 2011
- Open lung-sparing surgery for malignant pleural mesothelioma: the benefits of a radical approach within multimodality therapy☆European Journal of Cardio-Thoracic Surgery, 2008
- The optimal technique for combined application of fibrin sealant and bioabsorbable felt against alveolar air leakage☆☆☆European Journal of Cardio-Thoracic Surgery, 2008
- The short-term efficacy of fibrin glue combined with absorptive sheet material in visceral pleural defect repairInteractive CardioVascular and Thoracic Surgery, 2006
- Persistent air-leak following pulmonary resectionChest Surgery Clinics of North America, 2002