Validation of the ActiGraph wGT3X-BT Accelerometer for Step Counts at Five Different Body Locations in Laboratory Settings
Authors:
- 2 July 2021
- journal article
- research article
- Published by Taylor & Francis in Measurement in Physical Education and Exercise Science
- Vol. 26 (1) , 63-72
Abstract
This study aimed to determine the validity of the ActiGraph wGT3X-BT for step counts (SC) at five different body locations in laboratory settings. A total of 29 male adults participated in this study. The participants walked or ran for different speeds on the treadmill while wearing ActiGraph wGT3X-BT on their right wrist (RW), left wrist (LW), waist, right ankle (RA), and right upper arm (RUA). Both the video camera and each ActiGraph recorded SC simultaneously. The waist, RUA (6, 8, 10 km/hr and total), and RA (4 and 6 km/hr) showed small Mean Absolute Percentage Error (MAPE) values (<5%) and good agreement with Bland–Altman plots. However, the waist (2 and 4 km/hr), RUA (2 and 4 km/hr), RA (2, 8, 10 km/hr and total), RW, and LW showed high MAPE. In conclusion, the waist and RUA are valid for the total SC during walking and running in the laboratory setting.Keywords
Funding Information
- any grant from funding agencies in the public, commercial, or not-for-profit sectors
This publication has 46 references indexed in Scilit:
- Accuracy of StepWatch™ and ActiGraph Accelerometers for Measuring Steps Taken among Persons with Multiple SclerosisPLOS ONE, 2014
- Validity of the Acti4 software using ActiGraph GT3X+accelerometer for recording of arm and upper body inclination in simulated work tasksErgonomics, 2014
- Intermonitor reliability of the GT3X+ accelerometer at hip, wrist and ankle sites during activities of daily livingPhysiological Measurement, 2014
- What proportion of people with hip and knee osteoarthritis meet physical activity guidelines? A systematic review and meta-analysisOsteoarthritis and Cartilage, 2013
- Estimating Activity and Sedentary Behavior from an Accelerometer on the Hip or WristMedicine & Science in Sports & Exercise, 2013
- A step-defined sedentary lifestyle index: <5000 steps/dayApplied Physiology, Nutrition, and Metabolism, 2013
- Intermonitor Variability of GT3X AccelerometerInternational Journal of Sports Medicine, 2012
- Evaluation of Activity Monitors in Controlled and Free-Living EnvironmentsMedicine & Science in Sports & Exercise, 2012
- An assessment of self-reported physical activity instruments in young people for population surveillance: Project ALPHAInternational Journal of Behavioral Nutrition and Physical Activity, 2011
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986