Effects of temperature and pressure change on positive corona and sparkover under direct voltage in short airgaps
Authors:
- 5 July 2007
- journal article
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 1 (4) , 210-215
Abstract
Measurements are reported of breakdown voltage values and pre-breakdown voltage–current characteristics as a function of air density in a simple rod–plane electrode gap 50 mm in length. Pressure has been reduced and temperature raised from normal atmospheric values, independently of each other, to give the relative air densities in a common range less than unity. The effects of different diameters of rod have been studied. The results allow a comparison of the characteristics at equal relative air densities attained by either pressure or temperature adjustment. It is shown that at common relative air densities, breakdown is temperature- and geometry-dependent and that there is a temperature dependence of the pre-breakdown glow currents. The density-dependent relationship between the pre-breakdown glow discharge currents and breakdown voltages is discussed.Keywords
This publication has 3 references indexed in Scilit:
- Positive corona inception in air at elevated temperaturesIEE Proceedings - Science, Measurement and Technology, 2006
- Tests on the breakdown of air at elevatedtemperaturesin non-uniform electric fieldsIEE Proceedings - Science, Measurement and Technology, 2000
- Electrical Coronas1965