Premature Chromosome Condensation Assay for Biodosimetry; Studies with Fission-Neutrons

Authors:
  • CKC. J. Kolanko
    C. J. Kolanko
  • HGH. M. Gerstenberg
    H. M. Gerstenberg
  • WBW. F. Blakely
    W. F. Blakely

Abstract
Characterization of the premature chromosome condensation assay for radiation quality is needed. To that end, human lymphocytes were exposed in vitro to various doses of 250-kVp x rays (YD = 4 keV mM−1, YD is the dose-mean lineal energy of the absorbed dose distribution, D(y), where y is defined as the energy deposited in a volume by a single event divided by the mean chord length of the volume) and to fission neutrons (YD = 65 keV mM−1). The distribution of prematurely condensed chromosome and fragments following exposure to x rays or to neutrons were non-Poisson after repair at 37°C for 24 h. Dose-response curves were constructed for the yield of excess prematurely condensed chromosome fragments as necessary for biodosimetry applications. The curves were fitted to a weighted linear model by the least-squares regression method. The neutron relative biological effectiveness (RBE) value was estimated to be 2.4 ± 0.39.