Clinical Feasibility of Zero TE Skull MRI in Patients with Head Trauma in Comparison with CT: A Single-Center Study
Open Access
- 13 December 2018
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (1) , 109-115
Abstract
BACKGROUND AND PURPOSE: Conventional MR imaging techniques cannot produce optimal images of bone structures because bone has little water and a very short T2 life span. The aim of this study was to investigate the clinical feasibility of skull MR imaging using the zero TE sequence in patients with head trauma by assessing its diagnostic image quality and quantitative measurement compared with CT images. MATERIALS AND METHODS: Thirteen enrolled patients with head trauma were assessed using brain CT and skull MR imaging. Image quality was graded on a 5-point Likert scale to compare the 2 modalities. To evaluate quantitative analyses between the 2 imaging modalities, we measured skull thickness and normalized bone tissue signal. Interobserver reliability was assessed using weighted κ statistics and the intraclass correlation coefficient. RESULTS: Both imaging techniques clearly depicted skull fractures in all 13 patients. The mean scores for skull MR imaging and CT were 4.65 ± 0.56 and 4.73 ± 0.45 (P = .157), respectively, with substantial interobserver agreement (P < .05). The 2 imaging modalities showed no difference in skull thickness (P = .092) and had good correlation (r2 = 0.997). The mean value of normalized bone tissue signal among the 3 layers of the skull was relatively consistent (P = .401) with high interobserver agreement (P < .001). CONCLUSIONS: Zero TE skull MR imaging has diagnostic image quality comparable with that of CT images. It also provides consistent results on the quantitative measurement of cortical bone with CT images.Keywords
This publication has 26 references indexed in Scilit:
- Synthetic Mri of the Brain in a Clinical SettingActa Radiologica, 2012
- Correcting slice selectivity in hard pulse sequencesJournal of Magnetic Resonance, 2012
- Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA)Magnetic Resonance in Medicine, 2011
- Short T2 contrast with three-dimensional ultrashort echo time imagingMagnetic Resonance Imaging, 2011
- Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical boneJournal of Magnetic Resonance, 2010
- Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain PrototypeJournal of Nuclear Medicine, 2010
- MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time SequencesJournal of Nuclear Medicine, 2010
- Clinical ultrashort echo time imaging of bone and other connective tissuesNMR in Biomedicine, 2006
- Fast and quiet MRI using a swept radiofrequencyJournal of Magnetic Resonance, 2006
- Ultra‐fast imaging using low flip angles and fidsMagnetic Resonance in Medicine, 1995