Contrast and glare testing in keratoconus and after penetrating keratoplasty
Authors:
Open Access
- 1 May 2004
- journal article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 88 (5) , 653-657
Abstract
Aim: To compare the performance of keratoconus, penetrating keratoplasty (PK), and control subjects on clinical tests of contrast and glare vision, to determine whether differences in vision were independent of visual acuity (VA), and thereby establish which vision tests are the most useful for outcome studies of PK for keratoconus. Methods: All PK subjects had keratoconus before grafting and no subjects had any other eye disease. The keratoconus (n = 11, age 35.0 (SD 11.1) years), forme fruste keratoconus (n = 6, 33.0 (13.0)), PK (n = 21, 41.2 (7.9)), and control (n = 24, 33.7 (8.6)) groups were similar in age. Vision testing, conducted with optimal refractive correction in place, included low contrast visual acuity (LCVA) and Pelli-Robson contrast sensitivity (PRCS) both with and without glare, as well as VA. Results: Normal subjects saw better than PK subjects who in turn saw better than keratoconus subjects on all raw measures. However, when adjusted for VA, the normal group only saw significantly better than the keratoconus group on LCVA (low contrast loss 0.05 (0.04) v 0.15 (0.12), F2,48 = 6.16; pConclusions: PK subjects have superior vision to keratoconus subjects, but not as good as normal subjects. Including mild keratoconus subjects within a keratoconus group could confound these differences in vision. While VA is an excellent test for comparing normal, keratoconus and PK groups, additional information can be provided by LCVA and PRCS, but not by glare testing. Outcomes research into keratoconus management should include a measure in the contrast domain.Keywords
This publication has 42 references indexed in Scilit:
- Quality of life in myopiaBritish Journal of Ophthalmology, 2000
- Atopy and keratoconus: a multivariate analysisBritish Journal of Ophthalmology, 2000
- A small foveal avascular zone may be an historic mark of prematurityOphthalmology, 1999
- Visual Acuity Repeatability in Keratoconus: Impact on Sample SizeOptometry and Vision Science, 1998
- Measuring Resolution in the Contrast DomainOptometry and Vision Science, 1996
- The Clinical Management of KeratoconusEye & Contact Lens: Science & Clinical Practice, 1994
- Effect of Contact Lens Correction on Sine Wave Contrast Sensitivity in Keratoconus Patients after Penetrating KeratoplastyOptometry and Vision Science, 1992
- The reliability of the Pelli-Robson contrast sensitivity chartOphthalmic and Physiological Optics, 1990
- Rapid Contrast Sensitivity Assessment in KeratoconusOptometry and Vision Science, 1987
- CONTACT LENS CORRECTION OF VISUAL LOSS IN KERATOCONUSActa Ophthalmologica, 1982