Operation of aerial inspections vehicles in HVDC environments Part A: Evaluation and mitigation of high electrostatic field impact
Open Access
- 1 October 2019
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1356 (1) , 012009
Abstract
Offshore high voltage DC (HVDC) wind farms offer a promising solution to growing energy demands in the future. Condition monitoring of substation assets is essential for reliable and resilient operation of electrical networks. Existing condition monitoring techniques for onshore substation and electrical network assets include regular and scheduled on-site visits by trained personnel to substation sites. However, such routine inspection is not a cost-effective solution for offshore sites. In cases where the accessibility to network assets becomes difficult, robotic and autonomous condition monitoring provides a solution. Such a robotic/autonomous solution would need to interact with the surrounding substation environment, without increasing the risk of electrical breakdown and flashovers between different energized components. In Part A of this paper, the effect of high electrostatic fields on an inspection unmanned aerial vehicle (UAV) is analyzed, with respect to: 1) AC corona emissions interference on the UAV, and 2) Air breakdown clearance characteristics. Both simulations and experiment results presented in the paper show the impact of corona emissions interference to both UAV autopilot and actuation sections, which requires a shielding mitigation solution. Also, experiment results show the limited effect of introducing a shielding solution on increasing the flashover risk between valve hall towers.Keywords
This publication has 9 references indexed in Scilit:
- Seismic performance and restraint system of suspended 800 kV thyristor valveEngineering Structures, 2018
- 500 kV substation robot patrol system2017
- Mobile robot for power substation inspection: a surveyIEEE/CAA Journal of Automatica Sinica, 2017
- E-field distribution analysis on three types of converter double valve in 800kV valve hall2015
- LineScout Technology Opens the Way to Robotic Inspection and Maintenance of High-Voltage Power LinesIEEE Power and Energy Technology Systems Journal, 2015
- Mechanism of ±800kV HVDC converter abnormal block fault caused by lightning transientElectric Power Systems Research, 2014
- Cost-benefit Evaluation of Remote Inspection of Offshore Wind Farms by Simulating the Operation and Maintenance PhaseEnergy Procedia, 2014
- Development of a Novel Live-Line Inspection Robot System for Post Insulators at 220-kV SubstationsAdvanced Robotics, 2010
- Converter Stations for 800 kV HVDC2006