Comparison of diffusion‐weighted high‐resolution CBF and spin‐echo BOLD fMRI at 9.4 T
Authors:
- 28 March 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 47 (4) , 736-741
Abstract
The quantification of blood oxygenation‐level dependent (BOLD) functional MRI (fMRI) signals is closely related to cerebral blood flow (CBF) change; therefore, understanding the exact relationship between BOLD and CBF changes on a pixel‐by‐pixel basis is fundamental. In this study, quantitative CBF changes induced by neural activity were used to quantify BOLD signal changes during somatosensory stimulation in α‐chloralose‐anesthetized rats. To examine the influence of fast‐moving vascular spins in quantifying CBF, bipolar gradients were employed. Our data show no significant difference in relative CBF changes obtained with and without bipolar gradients. To compare BOLD and CBF signal changes induced by neural stimulation, a spin‐echo (SE) sequence with long SE time of 40 ms at 9.4 T was used in conjunction with an arterial spin labeling technique. SE BOLD changes were quantitatively correlated to CBF changes on a pixel‐by‐pixel and animal‐by‐animal basis. Thus, SE BOLD‐based fMRI at high magnetic fields allows a quantitative comparison of functional brain activities across brain regions and subjects. Magn Reson Med 47:736–741, 2002.Keywords
This publication has 30 references indexed in Scilit:
- Localized cerebral blood flow response at submillimeter columnar resolutionProceedings of the National Academy of Sciences, 2001
- Food For ThoughtAnnals of the New York Academy of Sciences, 1997
- Evidence for the exchange of arterial spin‐labeled water with tissue water in rat brain from diffusion‐sensitized measurements of perfusionMagnetic Resonance in Medicine, 1997
- Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniquesMagnetic Resonance in Medicine, 1997
- Mr perfusion studies with t1‐weighted echo planar imagingMagnetic Resonance in Medicine, 1995
- Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mappingMagnetic Resonance in Medicine, 1995
- Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical modelBiophysical Journal, 1993
- Effect of alpha‐chloralose, halothane, pentobarbital and nitrous oxide anesthesia on metabolic coupling in somatosensory cortex of ratActa Anaesthesiologica Scandinavica, 1992
- Perfusion imagingMagnetic Resonance in Medicine, 1992
- THE [14C]DEOXYGLUCOSE METHOD FOR THE MEASUREMENT OF LOCAL CEREBRAL GLUCOSE UTILIZATION: THEORY, PROCEDURE, AND NORMAL VALUES IN THE CONSCIOUS AND ANESTHETIZED ALBINO RAT1Journal of Neurochemistry, 1977