The Concentration of Krypton in the Atmosphere—Its Revision after Half a Century—
Authors:
- 17 September 2005
- journal article
- research article
- Published by Oxford University Press (OUP) in Chemistry Letters
- Vol. 34 (10) , 1396-1397
Abstract
During our attempt of the precise determination of trace gases in the atmosphere by using atmospheric krypton (Kr) as an internal standard, we noticed that the atmospheric Kr concentration of 1.14 ± 0.01 ppmv which had been quoted through half a century was different from the observation. The Kr concentration we obtained with three step concentration followed by GC/MS measurement was 1.099 ± 0.009 ppmv, about 4% lower than the currently used value.Keywords
This publication has 5 references indexed in Scilit:
- Precise Determination of the Atmospheric CF4 Concentration by Using Natural Kr in the Atmosphere as an Internal Reference in the Preconcentration/GC/MS AnalysisChemistry Letters, 2004
- Atomic weights of the elements. Review 2000 (IUPAC Technical Report)Pure and Applied Chemistry, 2003
- Freon 14 im „Krypton reinst” und in der AtmosphäreThe Science of Nature, 1974
- The krypton and xenon contents of atmospheric airProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1956
- On a new constituent of atmospheric airProceedings of the Royal Society of London, 1898