Can complex mitral valve repair be performed with robotics? An institution’s experience utilizing a dedicated team approach in 500 patients†
- 11 February 2019
- journal article
- conference paper
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 56 (3) , 470-478
Abstract
OBJECTIVES: The full potential of robotics has not been achieved in terms of addressing the most challenging mitral valve (MV) cases. We outline our technique and report our early results with totally endoscopic robotic MV repair in a wide range of pathologies.METHODS: From May 2011 to August 2017, a dedicated team attempted totally endoscopic robotic MV repair in 500 MV regurgitation patients. Repair complexity was scored in 3 categories. We analysed our sequential case experience by quartiles.RESULTS: Patient mean age was 60.8 years (range 18–88). Aetiologies included: degenerative 382 (76.4%), functional 37 (7.4%), inflammatory 22 (4.4%) and others 59 (11.8%). Mitral annular calcification was present in 64 (12.8%) cases. Simple MV repair (annuloplasty alone or with 1 leaflet segment repair) was performed in 240 (48%) patients, complex (repair involving more than 1 segment on the same leaflet) in 140 (28%) patients and most complex (bileaflet repair or mitral annular calcification excision with atrioventricular groove repair) in 120 (24%) patients. Concomitant procedures included: left appendage closure (94.8%), patent foramen ovale/atrial septal defect (PFO/ASD) closure (19.6%), cryoablation (19.4%), tricuspid repair (6.2%) or hybrid percutaneous coronary revascularization (7.8%). The overall repair rate was 99.4%, with 0.6% early mortality and 1.2% stroke rate (0.2% permanent neurological deficit). Case complexity increased with our experience. Despite an increase in aortic occlusion and perfusion times (median 86.5 and 125 min) and a slight decrease in operating room extubation rate (overall 64%), length of hospital stay (median 4 days) and 30-day readmission rate (overall 3.6%) were not affected by the progressive inclusion of more complex cases.CONCLUSIONS: Totally endoscopic robotic MV repair performed by a dedicated team allows one to address the entire spectrum of pathological complexity and provides consistent results.Keywords
Funding Information
- departmental funds from the authors’ institution
This publication has 13 references indexed in Scilit:
- Early results of robotically assisted mitral valve surgery: Analysis of the first 1000 casesThe Journal of Thoracic and Cardiovascular Surgery, 2018
- Robotic Mitral Valve Repair for Simple and Complex Degenerative DiseaseCirculation, 2015
- The Expanding Role of Endoscopic Robotics in Mitral Valve Surgery: 1,257 Consecutive ProceduresThe Annals of Thoracic Surgery, 2015
- Fluorescence-guided placement of an endoaortic balloon occlusion device for totally endoscopic robotic mitral valve repairThe Journal of Thoracic and Cardiovascular Surgery, 2015
- 540 Consecutive Robotic Mitral Valve Repairs Including Concomitant Atrial Fibrillation CryoablationThe Annals of Thoracic Surgery, 2012
- Endoscopic robotic mitral valve surgeryThe Journal of Thoracic and Cardiovascular Surgery, 2006
- Robotic mitral surgery at East Carolina University: a 6 year experienceThe International Journal of Medical Robotics and Computer Assisted Surgery, 2006
- Endoscopic coronary artery bypass grafting with the aid of robotic assisted instrumentsThe Journal of Thoracic and Cardiovascular Surgery, 1999
- Computer-assisted cardiac surgeryThe Lancet, 1999
- Cardiac valve surgery—the “French correction”The Journal of Thoracic and Cardiovascular Surgery, 1983