Clinical evaluation of a block sequential regularized expectation maximization reconstruction algorithm in 18F-FDG PET/CT studies
Authors:
- Paul StolzmannPSPaul Stolzmann
- Gaspar DelsoGDGaspar Delso
- Scott D. WollenweberSWScott D. Wollenweber
- Martin HüllnerMHMartin Hüllner
- Yahya A. HakamiYHYahya A. Hakami
- Marcelo A. QueirozMQMarcelo A. Queiroz
- Felipe de Galiza BarbosaFBFelipe de Galiza Barbosa
- Gustav K. von SchulthessGSGustav K. von Schulthess
- Carsten PietschCPCarsten Pietsch
- Patrick Veit-HaibachPVPatrick Veit-Haibach
- 1 January 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 38 (1) , 57-66
Abstract
To investigate the clinical performance of a block sequential regularized expectation maximization (BSREM) penalized likelihood reconstruction algorithm in oncologic PET/computed tomography (CT) studies. A total of 410 reconstructions of 41 fluorine-18 fluorodeoxyglucose-PET/CT studies of 41 patients with a total of 2010 lesions were analyzed by two experienced nuclear medicine physicians. Images were reconstructed with BSREM (with four different β values) or ordered subset expectation maximization (OSEM) algorithm with/without time-of-flight (TOF/non-TOF) corrections. OSEM reconstruction postfiltering was 4.0 mm full-width at half-maximum; BSREM did not use postfiltering. Evaluation of general image quality was performed with a five-point scale using maximum intensity projections. Artifacts (category 1), image sharpness (category 2), noise (category 3), and lesion detectability (category 4) were analyzed using a four-point scale. Size and maximum standardized uptake value (SUVmax) of lesions were measured by a third reader not involved in the image evaluation. BSREM-TOF reconstructions showed the best results in all categories, independent of different body compartments. In all categories, BSREM non-TOF reconstructions were significantly better than OSEM non-TOF reconstructions (P<0.001). In almost all categories, BSREM non-TOF reconstruction was comparable to or better than the OSEM-TOF algorithm (P<0.001 for general image quality, image sharpness, noise, and P=1.0 for artifact). Only in lesion detectability was OSEM-TOF significantly better than BSREM non-TOF (P<0.001). Both BSREM-TOF and BSREM non-TOF showed a decreasing SUVmax with increasing β values (P<0.001) and TOF reconstructions showed a significantly higher SUVmax than non-TOF reconstructions (P<0.001). The BSREM reconstruction algorithm showed a relevant improvement compared with OSEM reconstruction in PET/CT studies in all evaluated categories. BSREM might be used in clinical routine in conjunction with TOF to achieve better/higher image quality and lesion detectability or in PET/CT-systems without TOF-capability for enhancement of overall image quality as well.Keywords
This publication has 29 references indexed in Scilit:
- Diagnostic Performance of 18F-FDG-PET/CT in Vascular Graft InfectionsEuropean Journal of Vascular and Endovascular Surgery, 2015
- Update on Time-of-Flight PET ImagingJournal of Nuclear Medicine, 2014
- 18F-FDG Uptake in Noninfected Prosthetic Vascular Grafts: Incidence, Patterns, and Changes over TimeJournal of Nuclear Medicine, 2014
- The Pivotal Role of FDG-PET/CT in Modern MedicineAcademic Radiology, 2014
- Improvement in PET/CT Image Quality with a Combination of Point-Spread Function and Time-of-Flight in Relation to Reconstruction ParametersJournal of Nuclear Medicine, 2012
- Impact of Time-of-Flight PET on Whole-Body Oncologic Studies: A Human Observer Lesion Detection and Localization StudyJournal of Nuclear Medicine, 2011
- Improvement in Lesion Detection with Whole-Body Oncologic Time-of-Flight PETJournal of Nuclear Medicine, 2011
- Positron Emission Tomography-Computed Tomography Standardized Uptake Values in Clinical Practice and Assessing Response to TherapySeminars in Ultrasound, CT and MRI, 2010
- Benefit of Time-of-Flight in PET: Experimental and Clinical ResultsJournal of Nuclear Medicine, 2008
- Penalized maximum-likelihood image reconstruction for lesion detectionPhysics in Medicine & Biology, 2006