Measurement of the liquid argon energy response to nuclear and electronic recoils
Authors:
- P. AgnesPAP. Agnes
- J. DawsonJDJ. Dawson
- S. De CeccoSCS. De Cecco
- A. FanAFA. Fan
- G. FiorilloGFG. Fiorillo
- D. FrancoDFD. Franco
- C. GalbiatiCGC. Galbiati
- C. GigantiCGC. Giganti
- T. N. JohnsonTJT. N. Johnson
- G. KorgaGKG. Korga
- D. KrynDKD. Kryn
- M. LeboisMLM. Lebois
Open Access
- 19 June 2018
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review D
- Vol. 97 (11) , 112005
Abstract
A liquid argon time projection chamber, constructed for the Argon Response to Ionization and Scintillation (ARIS) experiment, is exposed to the highly collimated and quasimonoenergetic LICORNE neutron beam at the Institut de Physique Nucléaire d’Orsay (IPNO) in order to study the scintillation response to nuclear and electronic recoils. An array of liquid scintillator detectors, arranged around the apparatus, tag scattered neutrons and select nuclear recoil energies in the [7, 120] keV energy range. The relative scintillation efficiency of nuclear recoils is measured to high precision at null field, and the ion-electron recombination probability is extracted for a range of applied electric fields. Single-scattered Compton electrons, produced by gammas emitted from the deexcitation of in coincidence with the beam pulse, along with calibration gamma sources, are used to extract the recombination probability as a function of energy and electron drift field. The ARIS results are compared with three recombination probability parametrizations (Thomas-Imel, Doke-Birks, and PARIS), allowing for the definition of a fully comprehensive model of the liquid argon response to nuclear and electronic recoils down to the few-keV range. The constraints provided by ARIS to the liquid argon response at low energy allow the reduction of systematics affecting the sensitivity of dark matter search experiments based on liquid argon.
Keywords
All Related Versions
Funding Information
- National Science Foundation (PHY-1242585, PHY-1242611, PHY-1314501, PHY-1314483, PHY-1314507, PHY-1455351)
- Université Sorbonne Paris Cité (ANR-10-LABX-0023, ANR-11-IDEX-0005-02)
This publication has 21 references indexed in Scilit:
- Results from a Search for Dark Matter in the Complete LUX ExposurePhysical Review Letters, 2017
- Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy β and nuclear recoils in liquid argon with DEAP-1Astroparticle Physics, 2016
- Dark Matter Results from First 98.7 Days of Data from the PandaX-II ExperimentPhysical Review Letters, 2016
- Results from the first use of low radioactivity argon in a dark matter searchPhysical Review D, 2016
- The LICORNE Neutron Source and Measurements of Prompt γ-rays Emitted in FissionPhysics Procedia, 2014
- Development of a kinematically focused neutron source with the p(7Li,n)7Be inverse reactionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- The art frameworkJournal of Physics: Conference Series, 2012
- Calibration of liquid argon and neon detectors withPhysical Review C, 2010
- ROOT — An object oriented data analysis frameworkNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997
- EDEN: a neutron time-of-flight multidetector for decay studies of giant statesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993