Abstract
In order to provide effective test-retest and pooling of information from clinical gait analyses, it is critical to ensure that the data produced are as reliable as possible. Furthermore, it has been shown that anatomical marker placement is the largest source of inter-examiner variance in gait analyses. However, the effects of specific, known deviations in marker placement on calculated kinematic variables are unclear, and there is currently no mechanism to provide location-based feedback regarding placement consistency. The current study addresses these disparities by: applying a simulation of marker placement deviations to a large (n = 411) database of runners; evaluating a recently published method of morphometric-based deviation detection; and pilot-testing a system of location-based feedback for marker placements. Anatomical markers from a standing neutral trial were moved virtually by up to 30 mm to simulate deviations. Kinematic variables during running were then calculated using the original, and altered static trials. Results indicate that transverse plane angles at the knee and ankle are most sensitive to deviations in marker placement (7.59 degrees of change for every 10 mm of marker error), followed by frontal plane knee angles (5.17 degrees for every 10 mm). Evaluation of the deviation detection method demonstrated accuracies of up to 82% in classifying placements as deviant. Finally, pilot testing of a new methodology for providing location-based feedback demonstrated reductions of up to 80% in the deviation of outcome kinematics.Keywords
This publication has 20 references indexed in Scilit:
- Gender and Age-Related Differences in Bilateral Lower Extremity Mechanics during Treadmill RunningPLOS ONE, 2014
- Between-Limb Kinematic Asymmetry During Gait in Unilateral and Bilateral Mild to Moderate Knee OsteoarthritisArchives of Physical Medicine and Rehabilitation, 2013
- Reliability and minimal detectible change values for gait kinematics and kinetics in healthy adultsGait & Posture, 2012
- Assessment of a greater trochanter-based method of locating the hip joint centerJournal of Biomechanics, 2010
- Day-to-Day Consistency of Lower Extremity Kinematics during Walking and RunningJournal of Applied Biomechanics, 2009
- The reliability of three-dimensional kinematic gait measurements: A systematic reviewGait & Posture, 2009
- Human movement analysis using stereophotogrammetryGait & Posture, 2005
- A comparison of within‐ and between‐day reliability of discrete 3D lower extremity variables in runnersJournal of Orthopaedic Research, 2002
- Determining the movements of the skeleton using well-configured markersJournal of Biomechanics, 1993
- Application of the Joint Coordinate System to Three-Dimensional Joint Attitude and Movement Representation: A Standardization ProposalJournal of Biomechanical Engineering, 1993