Voltammetric Determination of Ternary Phenolic Antioxidants Mixtures with Peaks Separation by ICA
Authors:
- 16 December 2016
- journal article
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (2) , H42-H48
Abstract
The paper refers to the problem of separation of the overlapping signals in voltammetry, which was resolved by the assumption that the univariate calibration models for the individual analytes are requested. It was demonstrated that Independent Components Analysis (ICA) is an effective tool for reconstruction of the successive signals shape, peak positions and also the basic validation parameters meet the typical criteria. Simulation approach enabled selection of the optimal set of mixtures, necessary for the effective operation of the ICA and high predictive ability of the calibration models. It was proved that the triples of analytes chosen from the list of four phenolic acids, ie. caffeic of 9.9 – 87.6 μM, ferulic of 5.9 – 52.6 μM, syringic of 9.9 – 87.3 μM, and vanillic acid of 13.9 – 122.7 μM may be successfully simultaneously determined by differential pulse voltammetry on boron doped diamond electrode, excluding samples at concentrations close to the lower limit of linearity.Keywords
Funding Information
- Narodowe Centrum Nauki (National Science Centre) (2015/19/B/ST5/01380)
This publication has 36 references indexed in Scilit:
- Electroanalytical Measurements of Binary-Analyte Mixtures in Molten LiCl-KCl Eutectic: Gadolinium(III)- and Lanthanum(III)-ChlorideJournal of the Electrochemical Society, 2016
- pH Dependent Electrochemical Characterization, Computational Studies and Evaluation of Thermodynamic, Kinetic and Analytical Parameters of Two PhenazinesJournal of the Electrochemical Society, 2014
- Artificial Intelligence and Computational Intelligence2011
- Determination of Selenium Traces on Cyclic Renewable Mercury Film Silver Electrode in Presence of Copper Ions Using Cathodic Stripping VoltammetryElectroanalysis, 2008
- Dedicated mother wavelet in the determination of antimony in the presence of copperTalanta, 2008
- Voltammetric identification of multicomponent solutions using principal components analysisJournal of Analytical Chemistry, 2008
- Non-additive voltammetric currents from multicomponent systems of redox-active substancesElectrochimica Acta, 2005
- Optimization of smoothing process—the method to improve calibration in voltammetry: Part I. Simulated voltammogramsTalanta, 2004
- Quantitation in Multianalyte Overlapping Peaks from Capillary Electrophoresis Runs Using Artificial Neural NetworksJournal of Chromatographic Science, 2003
- Multicomponent Chemometric Determination of Colorant Mixtures by VoltammetryAnalytical Letters, 1997