Rapid assessment of bovine colostrum quality: How reliable are transmission infrared spectroscopy and digital and optical refractometers?
Authors:
- 1 February 2017
- journal article
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 100 (2) , 1427-1435
Abstract
The objectives of this study were to evaluate the performance of the transmission infrared (IR) spectroscopic method and digital and optical Brix refractometers for measurement of colostral IgG concentration and assessment of colostrum quality of dairy cows. Colostrum samples (n = 258) were collected from Holstein cows on 30 commercial dairy farms in Nova Scotia and Newfoundland, Canada. Colostral IgG concentrations of 255 samples were measured by the reference radial immunodiffusion (RID) assay and IR spectroscopy. The Brix scores were determined on 240 of these samples using both the digital and optical Brix refractometers. Approximately half (48%) of the colostrum samples had RID IgG concentrations <50 g/L, which was the cut-point for poor quality. The correlation between RID and IR IgG concentrations was 0.88. The correlations between RID IgG concentration and Brix scores, as determined by the digital and optical refractometers, were 0.72 and 0.71, respectively. The optimal cutoff levels for distinguishing good- and poor-quality colostrum using IR spectroscopy, and digital and optical Brix refractometers were at 35 g/L and 23% Brix, respectively. The IR spectroscopy showed higher sensitivity (90%) and specificity (86%) than the digital (74 and 80%, respectively) and optical (73 and 80%, respectively) Brix refractometers for assessment of colostrum quality, as compared with RID. In conclusion, the transmission-IR spectroscopy is a rapid and accurate method for assessing colostrum quality, but is a laboratory-based method, whereas Brix refractometers were less accurate but could be used on-farm.Keywords
This publication has 39 references indexed in Scilit:
- Assessment of different methods to estimate bovine colostrum quality on farmNew Zealand Veterinary Journal, 2016
- A novel method for the quantification of bovine colostral immunoglobulin G using infrared spectroscopyInternational Dairy Journal, 2016
- Quantification of bovine immunoglobulin G using transmission and attenuated total reflectance infrared spectroscopyJournal of Veterinary Diagnostic Investigation, 2015
- Evaluation of Digital and Optical Refractometers for Assessing Failure of Transfer of Passive Immunity in Dairy CalvesJournal of Veterinary Internal Medicine, 2015
- Evaluation of on-farm tools for colostrum quality measurementJournal of Dairy Science, 2015
- Use of Fourier-Transform Infrared Spectroscopy to Quantify Immunoglobulin G Concentrations in Alpaca SerumJournal of Veterinary Internal Medicine, 2014
- An evaluation of Brix refractometry instruments for measurement of colostrum quality in dairy cattleJournal of Dairy Science, 2010
- Comparison of four methods to assess colostral IgG concentration in dairy cowsJournal of the American Veterinary Medical Association, 2008
- Comparison of refractometers and test endpoints in the measurement of serum protein concentration to assess passive transfer status in calvesJournal of the American Veterinary Medical Association, 2002
- Associations between passive immunity and morbidity and mortality in dairy heifers in Florida, USAPreventive Veterinary Medicine, 1998